Security Settings - AMX Modero ViewPoint MVP-8400 Operation/Reference Manual

7.5" & 8.4” touch panels
Hide thumbs Also See for Modero ViewPoint MVP-8400:
Table of Contents

Advertisement

Security Settings

The Security button on the Protected Setup page has three settings: Standard Security, Secure, and
DoD. Each setting has different features for touch panel security:
Security Profile Features
Standard Security: • Factory default, shipped in this configuration.
Secure:
DOD:
Toggling between these three immediately and automatically resets the existing password to the default
password for that setting. With an unsecured panel using the Standard Security setting, the default
password is 1988. With panels using either the Secure or the DoD settings, the default password is
Amx1234! (paying attention to the case of the letters). Entering the existing password will not work and
the default will need to be entered at this point will allow access to the Protected Settings page and allow
resetting of the password to a new one.
If the Security button setting is changed in any way, even if it is toggled back to its
original setting, the password is automatically reset to the default for the chosen
setting. You MUST use the new default of 1988 (Standard Security) or Amx1234!
(Secure or DoD) to re-enter the Protected Settings page.
For more information on configuring AMX devices for a secure environment, please refer to the guide
Security Profiles: Configuring AMX Devices For Installation Into a Secure Environment, available at
www.amx.com.
MVP Modero ViewPoint Touch Panels
• Default Protected Setup Password is "1988".
• Remote login uses Telnet.
• Default Protected Setup Password is "Amx1234!".
• Minimum password requirement is 8 characters with at least one numeric character.
• Remote login uses SSH.
• Remote login user name is "amx".
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15
minutes.
• Login and logout audit logging is enabled.
• Default Protected Setup Password is "Amx1234!".
• Minimum password requirement is 8 characters with at least one numeric character,
one uppercase character, one lower case character, and one special character, with
no duplicate adjacent characters.
• Remote login uses SSH.
• Remote login user name is "amx".
• Login failure attempt pauses 4 seconds before another login attempt is allowed.
• After 3 consecutive unsuccessful SSH login attempts, login lockout is enabled for 15
minutes.
• Login and logout audit logging is enabled.
• DoD login banner is enabled.
Setup Pages
57

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Modero viewpoint mvp-7500

Table of Contents

Save Article as PDF