Pif; Sta; Sto - AMX Modero ViewPoint MVP-8400 Operation/Reference Manual

7.5" & 8.4” touch panels
Hide thumbs Also See for Modero ViewPoint MVP-8400:
Table of Contents

Advertisement

Button Query Commands (Cont.)

?PIF

Get the panel file
system, RAM, and
panel start time
information.

?STA

Get the XML
panel statistics.

?STO

Get the shutdown
timeout value.
MVP-7500/8400 Modero Viewpoint Wireless Touch Panels
Returned in Custom event.
Text=<Filesystem Info>,<RAM Info>,<Panel Start Time>
Returned in MULTIPLE Custom events (size of strings are limited per message). Values
in the Custom event displays the number of messages and how many total bytes of xml
data.
Value 1 = 1 (which one of multiple events is this (1 based))
Value 2 = 5 (total number of events required to send this string)
Value 3 = total size in bytes of string
Text = XML output (1 of 5)
total XML output looks like:
<?xml version="1.0" ?>
<PanelStats>
<Icsp>
<Total><Rx>11</Rx><Proc>11</Proc><Drop>0</Drop></Total>
<Rolling><Rx>11</Rx><Proc>11</Proc><Drop>0</Drop></Rolling>
</Icsp>
<Blink>
<Total><Rx>3</Rx><Miss>0</Miss></Total>
<Rolling><Rx>3</Rx><Miss>0</Miss></Rolling>
</Blink>
<Ethernet>
<RxPackets>53063571</RxPackets><RxErrors>0</RxErrors>
<RxDrops>0</RxDrops><RxOverRuns>0</RxOverRuns><RxFrames>63</
RxFrames>
<TxPackets>17842136</TxPackets><TxErrors>0</
TxErrors><TxDrops>0</TxDrops>
<TxOverRuns>0</TxOverRuns><TxCarriers>0</TxCarriers>
<Collisions>0</Collisions><TxQueueLen>100</TxQueueLen>
<RxBytes>292901735</RxBytes><TxBytes>1182103211</TxBytes>
</Ethernet>
<Wireless>
<Mode>Managed</Mode><Frequenc
Returned in Custom event.
Value1=shutdown timeout value (in minutes)