Programming
Page Commands (Cont.)

@PPK

Kill a specific
popup page from
all pages.

@PPM

Set the modality
of a specific
popup page to
Modal or
NonModal.

@PPN

Activate a
specific popup
page to launch on
either a specified
page or the
current page.

@PPT

Set a specific
popup page to
timeout within a
specified time.
114
Kill refers to the deactivating (Off) of a popup window from all pages. If the pop-up page is
part of a group, the whole group is deactivated. This command works in the same way as
the 'Clear Group' command in TPDesign 4.
Syntax:
"'@PPK-<popup page name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
Example:
SEND_COMMAND Panel,"'@PPK-Popup1'"
Kills the popup page 'Popup1' on all pages.
A Modal popup page, when active, only allows you to use the buttons and features on that
popup page. All other buttons on the panel page are inactivated.
Syntax:
"'@PPM-<popup page name>;<mode>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
mode = NONMODAL converts a previously Modal popup page to a NonModal.
MODAL converts a previously NonModal popup page to Modal.
modal = 1 and non-modal = 0
Example:
SEND_COMMAND Panel,"'@PPM-Popup1;Modal'"
Sets the popup page 'Popup1' to Modal.
SEND_COMMAND Panel,"'@PPM-Popup1;1'"
Sets the popup page 'Popup1' to Modal.
If the page name is empty, the current page is used (see example 2). If the popup page is
already on, do not re-draw it. This command works in the same way as the 'Show Popup'
command in TPDesign4.
Syntax:
"'@PPN-<popup page name>;<page name>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
page name = 1 - 50 ASCII characters. Name of the page the popup is displayed On.
Example:
SEND_COMMAND Panel,"'@PPN-Popup1;Main'"
Activates 'Popup1' on the 'Main' page.
Example 2:
SEND_COMMAND Panel,"'@PPN-Popup1'"
Activates the popup page 'Popup1' on the current page.
If timeout is empty, popup page will clear the timeout.
Syntax:
"'@PPT-<popup page name>;<timeout>'"
Variable:
popup page name = 1 - 50 ASCII characters. Name of the popup page.
timeout = Timeout duration in 1/10ths of a second.
Example:
SEND_COMMAND Panel,"'@PPT-Popup1;30'"
Sets the popup page 'Popup1' to timeout within 3 seconds.