Exmark Lazer Z HP Operator's Manual page 25

Hide thumbs Also See for Lazer Z HP:
Table of Contents

Advertisement

For Exmark Mower Parts Call 606-678-9623 or 606-561-4983
5.1.5
Note: To prevent damage due to freezing, battery should be fully charged
before putting away for winter storage.
a)
Check the voltage of the battery with a digital voltmeter. Locate the voltage
reading of the battery in the table below and charge the battery for the
recommended time interval to bring the charge up to a full charge of 12.6
volts or greater.
IMPORTANT: Make sure the negative battery cables are disconnected
and the battery charger used for charging the battery has an output of 16
volts and 7 amps or less to avoid damaging the battery (see chart below
for recommended charger settings).
Voltage
Reading
12.6 or greater
12.4 – 12.6
12.2 – 12.4
12.0 – 12.2
11.7 – 12.0
11.7 or less
5.1.4 Clean grass build-up under deck.
a)
Stop engine, wait for all moving parts to stop, and remove key.
b)
Raise deck to the transport (4.5" cutting height) position. Lift the front of
unit and support unit using jack stands or equivalent support.
POTENTIAL HAZARD
♦ Raising the mower deck for service or maintenance
relying solely on mechanical or hydraulic jacks could
be dangerous.
WHAT CAN HAPPEN
♦ The mechanical or hydraulic jacks may not be enough
support or may misfunction allowing the unit to fall,
which could cause injury.
HOW TO AVOID THE HAZARD
♦ DO NOT rely solely on mechanical or hydraulic jacks
for support. Use adequate jack stands or equivalent
support.
c)
Clean out any grass build-up from underside of deck and in deck
discharge chute.
Check mower blades.
a)
Stop engine, wait for all moving parts to stop, and remove key.
b)
Lift deck and secure in raised position as stated in Section 5.1.4.
c)
Inspect blades and sharpen or replace as required.
d)
Re-install the blades (if they were removed) by placing a block of wood
between the front or rear baffles and the blade then torque the blade
bolts to 115-120 ft. lbs. Be sure the spring disk washer cone is installed
toward the bolt head. (See Figure 4).
www.mymowerparts.com
Percent
Maximum
Charge
Charger Settings
100%
16 volts/7 amps
75 – 100%
16 volts/7 amps
50 – 75%
16 volts/7 amps
25 – 50%
14.4 volts/4 amps
0 – 25%
14.4 volts/4 amps
0%
14.4 volts/2 amps
Service Interval: Daily
CAUTION
Service Interval: Daily
- 20 -
Charging Interval
No Charging Required
30 Minutes
1 Hour
2 Hours
3 Hours
6 Hours or More

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents