Upgrading Modero Firmware
FIG. 73 Assigning Communication Settings and TCP/IP Settings
9. From within the TCP/IP dialog click New to enter the IP information for a new IP Address or
select from the list of previously entered IP Address and alter their properties by clicking the
Edit button and making your changes.
10. Enter the IP Address into the TCP/IP Address field. This information is obtained from either
your System Administrator or obtained from the Master.
11. Click OK when you are done adding or editing the IP Address from the New/Edit TCP/IP
Setting dialog.
12. Click OK three more times to close the open dialogs and save your settings.
13. Click Yes to interrupt the current communication from the Master and apply the new settings.
14. Select Tools > Reboot the Master Controller to access the Reboot the Master dialog, then
click Reboot to reboot the Master and incorporate any changes.
15. Once the dialog replies with "Reboot of system complete", press Done.
16. Click the OnLine Tree tab in the Workspace window to view the devices on the System. The
default System value is one.
17. Right-click on the Empty Device Tree/System entry and select Refresh System to re-populate
the list.

Step 2: Prepare the panel for communication via an IP

1. Press the blue Type field (from the Master Connection section) until the choice cycles to the
word Ethernet.
2. Press the blue Mode field until the choice cycles to the word URL.
3. Press the red Master IP/URL field to open a Keyboard and enter the NetLinx Master's
IP Address (obtained from the Diagnostics - Networking Address dialog of the NetLinx
Studio application).
82
By selecting URL, the System Number field becomes read-only (grey) because the panel
pulls this value directly from the communicating target Master (virtual or not). A Virtual
Master system value can be set within the active AMX software applications such as:
NetLinx Studio, TPD4, or IREdit.
List of previously saved IP Addresses