Electrical Precautions - Chicago Electric 95189 Operating Instructions Manual

2200 rated watts/2400 max watts
Table of Contents

Advertisement

Prolonged exposure to noise levels above 85 dBA is hazardous to hearing.
Always wear ANSI approved ear protection when operating or working around the
Generator when it is running.
1.
All connections and conduits from the Generator to the load must only be
installed by trained and licensed electricians, and in compliance with all
relevant local, state, and federal electrical codes and standards, and other
regulations where applicable.
2.
The Generator must be earth-grounded in accordance with all relevant electri-
cal codes and standards before operation.
if an extension cord (not included) is used, make sure to use only uL listed
3.
cords having the correct gauge and length. (See TABLE A)
REQuiRED MiNiMuM EXTENSiON cORD GAuGE - 120 VOLT
NAMEPLATE
AMPERES
(at full load)
0 – 5
5.1 – 8
8.1 – 12
12.1 – 15
15.1 – 20
TABLE A
4.
Do not attempt to connect or disconnect load connections while standing in
water, or on wet or soggy ground.
5.
Do not touch electrically energized parts of the Generator and interconnect-
ing cables or conductors with any part of the body, or with any non-insulated
conductive object.
6.
connect the Generator only to a load or electrical system (115 volt) that is
compatible with the electrical characteristics and rated capacities of the
Generator.
7.
Before servicing equipment powered by the Generator, disconnect the equip-
ment from its power input.
SKU 95189
For technical questions, please call 1-800-444-3353.
NOiSE PREcAuTiON

ELEcTRicAL PREcAuTiONS

EXTENSiON cORD LENGTh
0-25 Feet
25-50 Feet
16
16
16
16
14
14
12
12
10
10
50-100 Feet
100-150 Feet
16
12
14
10
12
-
10
-
10
-
150-200 Feet
12
-
-
-
-
Page 10