Chicago Electric 95126 Assembly And Operating Instructions Manual

Chicago Electric 95126 Assembly And Operating Instructions Manual

Gasoline generator 3500w

Advertisement

GASOLINE GENERATOR
3500W
Model 95126
ASSEMBLY AND OPERATING INSTRUCTIONS
Do to continuing improvements, actual product may differ slighlty from the product described herein.
CAUTION!
Your Warranty Is Voided If:
A. You do not put engine oil in the Engine's crankcase prior to its first use.
Before each use, check the oil level. Never run the Engine with low or no engine oil.
Running the Engine with low or no oil will permanently damage the unit.
®
3491 Mission Oaks Blvd., Camarillo, CA 93011
Visit our Web site at: http://www.harborfreight.com
TO PREVENT SERIOUS INJURY,
READ AND UNDERSTAND ALL WARNINGS
AND INSTRUCTIONS BEFORE USE.
©
®
Copyright 2006 by Harbor Freight Tools
. All rights reserved. No portion of this
manual or any artwork contained herein may be reproduced in any shape or form
without the express written consent of Harbor Freight Tools.
For technical questions, please call 1-800-444-3353.

Advertisement

Table of Contents
loading

Summary of Contents for Chicago Electric 95126

  • Page 1 GASOLINE GENERATOR 3500W Model 95126 ASSEMBLY AND OPERATING INSTRUCTIONS Do to continuing improvements, actual product may differ slighlty from the product described herein. CAUTION! Your Warranty Is Voided If: A. You do not put engine oil in the Engine’s crankcase prior to its first use.
  • Page 2: Product Specifications

    Keep your work area clean and well lit. Cluttered benches and dark areas invite accidents. Do not operate power tools in explosive atmospheres, such as in the presence of flammable liquids, gases, or dust. Power tools create SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 2...
  • Page 3: Personal Safety

    Maintain tools with care. Properly maintained tools are less likely to malfunction and are easier to control. Do not use a damaged tool. Tag damaged SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 3...
  • Page 4: Specific Safety Rules And Precautions

    Industrial applications must follow OSHA guidelines. Never stand on the Generator. Serious injury could result if the Generator is tipped. Never leave the Generator unattended when it is running. Turn off the Engine before leaving. SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 4...
  • Page 5: Fire And Explosion Precautions

    Use only Engine manufacturer recommended fuel and oil. MECHANICAL PRECAUTIONS Prior to performing service, maintenance, or cleaning procedures, always make sure the Engine’s Ignition is in its “OFF” position. Allow the Engine SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 5...
  • Page 6: Chemical Precautions

    Do not touch electrically energized parts of the Generator and interconnecting cables or conductors with any part of the body, or with any non-insulated conductive object. SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 6...
  • Page 7 Use only Class BC or Class ABC fire extinguishers on electrical fires. RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS (120 VOLT) RECOMMENDED MINIMUM WIRE GAUGE FOR EXTENSION CORDS (240 VOLT) FIGURE A SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 7...
  • Page 8: Product Features

    240 VAC Outlet (72): Use to connect electrical devices that run 240 volt, 60 Hz, single phase, AC current. (See Figure B.) Ground Terminal (10): Connect grounding wires here to properly ground unit. (See Figure B.) FIGURE B SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 8...
  • Page 9 Fuel Gauge (47): Indicates the amount of fuel in the Fuel Tank. (See Figure B.) Fuel Cap (44): Provides access to the Fuel Tank for adding fuel. (See Figure B.) Voltmeter (21): Provides readings of voltage output. (See Figure B.) SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 9...
  • Page 10: Installation Instructions

    24 inches deep into the earth. The grounding rod must be an earth-driven copper or brass rod (electrode) which can adequately ground the Generator. (See Figure C, next page.) SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 10...
  • Page 11: Pre-Start Instructions

    (approximately 3.96 gallons). (See Figure D.) To do so, remove the Fuel Cap (44) and fill the Fuel Tank (43) with unleaded gasoline. Then, replace the Fuel Cap. Thereafter, check the Fuel Gauge (47) for SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 11...
  • Page 12: Operating Instructions

    If necessary, repeat this procedure until the Engine starts. (See Figure B.) When the Engine starts, slowly move the Choke Lever (79) to its “RUN” position. (See Figure B.) SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 12...
  • Page 13 Generator. Plug voltage sensitive items such as T.V.’s, VCR’s, ® microwaves, and cordless telephones into a UL listed voltage surge protector ® (not included). Then, connect the UL Listed surge protector into the Generator. SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 13...
  • Page 14: Inspection, Maintenance, And Cleaning

    C. Do not use a garden hose or anything with liquid to clean the Generator. Liquid may enter the cooling air slots and could damage the interior workings of the Generator. SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 14...
  • Page 15: Please Read The Following Carefully

    ASSUMES ALL RISKS AND LIABILITY ARISING OUT OF HIS OR HER REPAIRS TO THE ORIGINAL PRODUCT OR REPLACEMENT PARTS THERETO, OR ARISING OUT OF HIS OR HER INSTALLATION OF REPLACEMENT PARTS THERETO. SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 15...
  • Page 16: Troubleshooting

    TROUBLESHOOTING SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 16...
  • Page 17: Parts List

    Bolt (M5 x 14) ------- --------------------------------- ------ Stator & Rotor Assy. ------- --------------------------------- ------ NOTE: Some parts are listed and shown for illustration purposes only, and are not available individually as replacement parts. SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 17...
  • Page 18: Assembly Diagram

    ASSEMBLY DIAGRAM SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 18...
  • Page 19: Wiring Diagram

    WIRING DIAGRAM SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 19...
  • Page 20: Emission Control System Warranty

    (d) improper or inadequate maintenance of any warranted parts (e) repairs performed outside of the authorized warranty service dealers alterations by changing, adding to or removing parts from the engine. SKU 95126 For technical questions, please call 1-800-444-3353 PAGE 20...
  • Page 21: Warranty

    This warranty gives you specific legal rights and you may also have other rights which vary from state to state. 3491 Mission Oaks Blvd. • PO Box 6009 • Camarillo, CA 93011 • (800) 444-3353 SKU 95126 For technical questions, please call 1-800-444-3353...