Trigger Zone Fault Report

When armed by remote command the system runs a status check
of the alarm trigger zones. Faulty zones (usually caused by dome
light delay or open trunk) are bypassed and reported via the control
center LED and remote, while all other trigger zones remain active
and are monitored to protect the vehicle. Should a faulty zone self
correct (dome light turns off) it becomes active and is then monitored
normally.
The siren chirps once again a few seconds following the arming
chirps as an audible alert, the control center LED flashes in groups to
indicate the zone number.

Alarm Report

If the alarm was triggered while armed, it will be reported when
the alarm is disarmed via the remote control, siren chirps, parking
light and control center LED flashes. The siren chirps four times (or five
times if NPC On*), the parking lights flash three times, and the control
center LED flashes in groups to indicate the last two zones that were
triggered (see Table of Zones). The report output will repeat for each
disarm operation until the ignition is turned on.
Zone # (led flashes)
1
2
3
4
5
6
26
Table of Zones
Zone Name
Trunk
Shock Sensor
Door
Sensor 2
Ignition
Hood