Connecting the cable (Continued)
12
E-
Wiring Diagram of Connection Cord
1(L) 2(N) VC VC
Outdoor Unit
Note
Ground wire for the indoor unit and outdoor unit connection
cable must be clamped to a soft
copper tin-plated eyelet terminal with M4 screw hole(NOT
SUPPLIED WITH UNIT ACCESSORIES).

Connecting the Power Terminal

Connect the cables to the terminal board using the compressed ring terminal.
Connect the rated cables only.
Connect using a driver which is able to apply the rated torque to the screws.
If the terminal is loose, fire may occur caused by arc.
If the terminal is connected too firmly, the terminal may be damaged.
Tightening Torque (ft.lb (kgf • cm))
M3
0.43(5.9)
Indoor Unit
F1 F2 V1 V2 F3 F4
Outdoor Unit
F1
F2
1(L) 2(N)
1 phase, 208-230V~
L
N

Advertisement