B. Place the two steel bar springs and the drive belt tensioning roller plate under the
front bracket on the drive belt tensioning assembly. Be sure springs are firmly
seated against the stop under the drive belt retainer. See Figure 5.
C. Place the washers and mounting bolt on top of the drive belt tensioning assembly.
See Figure 5. Tighten the mounting bolt while keeping drive belt aligned with the
drive pulley and the front roller pulley.
NOTE: The lower control board is labeled tired" and "black". When connecting the drive
16. Connect the motor cables.
A. Connect the red and black motor cables into the lower control board. The red
cable should go where the board is labeled "red" and the black cable "black". See
Figure 11.
Motor
Figure 11
Page 5-12
Cybex 600T Treadmill Service Manual
motor cables, make sure that the red wire plugs into the red and black wire plugs
into the black.