4.3
CD changer mechanism adjustment
When a mechanism or a printed circuit board, it is required to write a mechanism position in E2PROM.
A write-in procedure
step1 : Press together the Reverse key (main body) and Clock key of main body at standby condition.
step2 : Keep this condition then power switch to turn ON.
step3 : Mechanism done the initialize opelationautomaticaly.
step4 : Complete the initialize operation.
step5 : Power switch to turn OFF.
step6 : Complete the write-in to E2PROM.
(No.MB043)1-37