Type 3254.331 Heat Pump With Mechanical Controls Installation And Operating Instructions

SPECIFICATIONS

Type
Nominal Capacity (KW)
Electrical Rating
220 - 240 VAC 50 Hz. 1Ph.
FL Amps (Comp/Motor)
LR Amps (Comp/Motor)
Power (KW)
Min. Wire Size
Up to 8 M, use 1.5 mm2 Copper
Circuit Protection
10 Amp Time Delay Fuse or
10 Amp Circuit Breaker
Generator Size
1 Unit
3.5 KW
2 Units
5.0 KW
The Manufacturer gives only general guidelines for Generator
requirements. These Generator requirements come from
experiences consumers have with our equipment in field
applications. When sizing Generators, the total electrical
power consumption of the caravan must be considered. Keep
in mind that Generators lose power because of altitude
increase above sea level, high outside temperatures and lack
of maintenance.

INSTALLATION INSTRUCTIONS

A. Precautions
!
WARNING
Improper installation may damage equipment,
could endanger life, cause serious injury and/
or property damage.
1. Read Installation and Operating Instructions care-
fully before attempting to start your air conditioner
installation.
2. Dometic Corporation will not be liable for any dam-
ages or injury incurred due to failure in following
these instructions.
3. Installation must comply with All National Electrical
Codes or Local Codes or regulations.
4. DO NOT add any devices or accessories to this air
conditioner except those specifically authorized by
Dometic.
5. This equipment must be serviced by qualified per-
sonnel and some localities require these people to
be licensed.
3254.331
Heat Pump
3.2
5.2/0.9
26.0/4.4
1.3
B. Choosing Proper Location For The Air
Conditioner
This air conditioner is specifically designed for installa-
tion on the roof of a Caravan. When determining your
cooling requirements, the following should be consid-
ered:
Size of Caravan;
Window area (increases heat gain);
Amount of insulation in walls and roof;
Geographical location where the Caravan
will be used;
Personal comfort level required.
1. Normal Location-The air conditioner is designed to
fit over an existing roof vent opening. See FIG. 1.
FIG. 1
2. Other Locations-When no roof vent is available or
another location is desired, the following is recom-
mended:
a. For one unit installation: The air conditioner
should be mounted slightly forward of center
(front to back) and centered from side to side.
See FIG. 2.
FIG. 2
1/2L
b. For two unit installations: Install one Air Condi-
tioner 1/3 and one Air Conditioner 2/3's from
front of Caravan and centered from side to side.
See FIG. 2.
3
L
L
2/3L
1/3L