SPECIFICATIONS

A.
Table - Unit Data
Model No.
Nominal
Electrical
Capacity
Rating*
(BTU HR)
Cooling
441003.701
10,150
120 Vac
60 Hz 1 ph
441003A701
10,150
*
Maximum unit performance achieved at full rated voltage.
** For wire length over 24 ft., consult the National Electrical Code for proper sizing.
*** Dometic Corporation gives GENERAL guidelines for generator requirements. These guidelines come from experiences
people have had in actual applications. When sizing the generator, the total power usage of your RV must be considered.
Keep in mind generators lose power at high altitudes and from lack of maintenance.
**** CIRCUIT PROTECTION: Time Delay Fuse or Circuit Breaker Required.
B.

Interior Compartment/Sidewall Opening Requirements

1. A dedicated interior compartment MUST BE provided for the unit installation. This compartment MUST BE OPEN
TO THE OUTSIDE AND AIR SEALED TO THE INSIDE. Interior compartment must be at least 20" deep with an
inside cabinet front cutout of 20" x 14". The opening must be 1" above the mounting surface for the unit.
2. A 22-3/4" wide x 15" high opening through the sidewall or outside panel is required.
Compressor
Compressor
Fan Motor
Rated Load
Locked
Rated Load
Amps
Rotor
Amps
Amps
8.9
50.0
2.2
8.9
50.0
2.2
Fan Motor
Refrigerant
Minimum
Locked
R-410A
Wire Size**
Rotor
(oz)
Amps
6.6
28.0
12 AWG
Copper
6.6
28.0
Up to 24'
5
AC Circuit
Minimum
Unit
Protection
Generator
Width
****Installer
Size***
Supplied
1 Unit / 2 Units
20 Amp
2.8 kW / 40 kW
22"
20 Amp
2.8 kW / 4.0 kW
22"
Unit
Unit
Installed
Height
Depth
Weight
(Pounds)
14.5"
20.5"
70
14.5"
20.5"
70