LOW COOL: Selected when room at desired 7) The Dometic Corporation will not be liable for any comfort level and needs to be maintained. damages or injury incurred due to failure in following Normally this speed used for night time opera- these instructions.
Page 3
NOTE: The blower runs continuously to circulate air and Air conditioners have a greater tendency to frost when maintain an even temperature. The compressor will the outside temperature is relatively low. This may be come on as cooling is required to maintain the se- prevented by adjusting the thermostat control knob to lected temperature level.
A. PRECAUTIONS fully before starting your air conditioner installa- tion. ! DANGER 2) The Dometic Corporation will not be liable for any IMPROPER INSTALLATION MAY DAMAGE damages or injury incurred due to failure in follow- EQUIPMENT, COULD ENDANGER LIFE, ing these instructions.
Page 5
FRAME OPENING SO IT 3/4" MIN. C. ROOF PREPARATION WON'T COLLAPSE WHEN 1) ROOF VENT REMOVAL: BOLTING DOWN AIR CONDITIONER a) Unscrew and remove the roof vent. b) Remove all caulking compound around opening. c) Seal all screw holes and seams where the roof gasket will be located.
Page 6
a) Remove upper duct from ceiling template and locate it over blower discharge. NOTE: Edges without flanges install toward REAR and SIDE of opening. b) Use two (2) sharp pointed #10 x 1/2" sheet metal screws (A) to hold duct to base pan. Holes provided in bottom of basepan for these screws to go into.
Page 7
3105975 AIR DISTRIBUTION BOX 3107209 AIR DISTRIBUTION BOX CORNER REINFORCEMENT MOUNTING BOLT (B) (TYP.) WOOD SCREW (C) UNIT JUNCTION MOUNTING BOLT UNIT ELECTRICAL CORD MOUNTING BOLT (B) FRONT OF COACH DISCHARGE A IR WOOD SCREW DUCT MOUNTING BOLT (B) CORNER NUT RETAINER 2) Connect white wire in junction box to white or neutral wire from supply line.
Page 8
3105975 AIR DISTRIBUTION BOX 3107209 AIR DISTRIBUTION BOX CEILING T EMPLATE WELD ST UDS WOOD SCR EW (C) WOOD SCR EW (C) MACHINE SCREW (F ) NUT (G) WOOD SCR EW (C) COVER P LATE (H) WOOD SCREW (C) PUSH/PULL FASTENERS RETURN A IR GR ILLE MOUNTING PARTS...
Page 9
H. INSTALLATION ON TENT CAMPER AIR CONDITIONING UNIT ROOF 1) The permanent wiring leading to unit junc- tion box may originate in a flanged surface inlet located in roof section near the side wall. 2) A unique outlet receptacle for air condi- tioner should be located in the side wall of vehicle beneath the flanged surface inlet.
Page 10
This Manual is Compliments of Northwest RV Supply 86325 College View Road Eugene, OR 97405 Local: 541-746-9092 Toll-Free: 866-678-7467 Fax: 541-736-5573 http://www.nwrvsupply.com mail@nwrvsupply.com Northwest RV Supply carries a large spectrum of surplus, used, and new RV parts and components. Please feel free to visit our website for additional information.