Meter Setting And Adjustment - Toshiba TOSVERT VF-S11 Instruction Manual

New global standard inverter
Hide thumbs Also See for TOSVERT VF-S11:
Table of Contents

Advertisement

To make changes in the command mode selection
(Can be changed while in operation when
Preset-speed operation
5.5

Meter setting and adjustment

• Function
The signal output from the FM terminal is an analog voltage signal.
5
For the meter, use either a full-scale 0-1mAdc ammeter or full-scale 0-7.5Vdc (or 10Vdc-1mA) voltmeter.
Switching to 0-20mAdc (4-20mAdc) current input can be made by turning the FM slide switch to
the I position. When switching to 4-20mAdc current input, make adjustments using
log output gradient) and
[Connected meter selection parameters]
Title
, first stop the inverter temporarily.
: Set to
(Terminal board).
: Valid in all setting values.
: Meter selection
: Meter adjustment
Function
Meter selection
Meter adjustment
and the frequency setting mode selection 1
is set to
.)
(analog output bias).
Adjustment range
0: Output frequency
1: Output current
2: Set frequency
3: DC voltage
4: Output voltage command value
5: Input power
6: Output power
7: Torque
8: Torque current
9: Motor cumulative load factor
10: Inverter cumulative load factor
11: PBR (braking reactor) cumulative load factor
12: Frequency setting value (after PID)
13: VIA/II Input value
14: VIB Input value
15: Fixed output 1 (Output current: 100%)
16: Fixed output 2 (Output current: 50%)
17: Fixed output 3
(Other than the output current: 100%)
18: Serial communication data
19: For adjustments (
set value is displayed.)
-
E-10
E6581158
(ana-
Default setting
0
-