Termination Clearances - Vermont Castings RADVTCB Homeowner's Installation And Operating Manual

Radvt series and radvtcs series radiance direct vent gas heater
Table of Contents

Advertisement

Radiance Direct Vent Gas Heater

Termination Clearances

Termination clearances for buildings with combustible and noncombustible exteriors.
Inside Corner
G =
Combustible
G
6" (152 mm)
Noncombustible
V
2" (51 mm)
Balcony -
with no side wall
M
V
M =
Combustible &
Noncombustible
12" (305 mm)
*NOTE: Termination in an alcove space (spaces open only on one side and with an overhang) is permitted with the dimensions
specified for vinyl or non-vinyl siding and soffits. 1. There must be a 3' (914 mm) minimum between termination caps. . All
mechanical air intakes within 10' (1 m) of a termination cap must be a minimum of 3' (914 mm) below the termination cap. 3. All
gravity air intakes within 3' (914 mm) of a termination cap must be a minimum of 1' (305 mm) below the termination cap.
Fig. 12 Termination clearances.
11
Outside Corner
F =
Combustible
6" (152 mm)
Noncombustible
V
2" (51 mm)
F
Balcony -
with perpendicular side wall
M
V
P
Combustible &
Noncombustible
M = 24" (610 mm)
P = 20" (508 mm)
Alcove Applications*
D
C
C
V
E
O
E
= Min. 6" (152 mm) for
non-vinyl sidewalls
Min. 12" (305 mm) for
vinyl sidewalls
O
= 8' (2.4 m) Min.
No.
of Caps
D
Min.
1
3' (914 mm)  x D

6' (1.8 m)
3
9' (.7 m)
4
1' (3.7 m)
D
= # of Termination caps x 3
Min.
C
= ( / # termination caps) x D
Max.
C
Max.
Actual
1 x D
Actual
/3 x D
Actual
1/ x D
Actual
584-15
Actual
30004967