Electrical Information; Wiring Requirements; Intellifire Plus™ Ignition System Wiring; Optional Accessories Requirements - Heat & Glo 6TRSI-AUD Owner's Manual

Natural gas, propane or butane as a balanced flue heater
Hide thumbs Also See for 6TRSI-AUD:
Table of Contents

Advertisement

12
12

Electrical Information

A. Wiring Requirements
NOTICE: This appliance must be installed by a qualifi ed
electrician in accordance with the relevant national and
local regulations.
• Wire the appliance junction cord to 220/240 VAC. This
is required for proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
220/240 VAC to the valve or to the appliance wall switch.
Incorrect wiring will damage controls.
NOTICE: The mains supply to the appliance must have
isolation of a minimum 3 mm contact separation in both
poles.
WARNING! Risk of Injury! The gas supply shall be shut
off prior to disconnecting the electrical power and remov-
ing batteries (if installed) before proceeding with any
maintenance to the appliance.
B. IntelliFire Plus™ Ignition System Wiring
• Wire the appliance junction cord to 220/240 VAC for
proper operation of the appliance.
WARNING! Risk of Shock or Explosion! DO NOT wire
IPI controlled appliance junction cord to a switched cir-
cuit. Incorrect wiring will override IPI safety lockout.
• Refer to Figure 12.1, IntelliFire Plus™ Pilot Ignition (IPI)
Wiring Diagram.
• This appliance is equipped with an IntelliFire Plus™
control valve which operates on a 6 volt system.
Figure 12.1 IPI Wiring Diagram /RC300AU
6V DC SUPPLY
DC REGULATOR
CONTROL MODULE
JUNCTION CORD
ORANGE
GREEN
(PILOT)
(MAIN)
Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14
• For units installed in Australia, the residence's 220/240
VAC wall outlet to which this appliance's power cord is
connected, must be wired to an in-line on/off switch.
This is required for servicing and/or resetting the control
module in the event of a control module LOCK-OUT.
• Plug the 6-volt AC power supply into the appliance junction
cord to supply power to the unit.
C. Optional Accessories Requirements
• This appliance may be used with a wall switch, wall
mounted thermostat and/or a remote control.
Wiring for optional Hearth & Home Technologies approved
accessories should be done now to avoid reconstruction.
Follow instructions that come with those accessories.
Optional Remote Control Receiver Location
The control module and remote control receiver can be
accessed through the air space below the fi rebox front
and the lower access door.
The IPI control module and the remote control receiver
are placed on the fi rebox bottom.
WARNING! Risk of Shock! Label all wires prior to dis-
connection when servicing controls. Wiring errors can
cause improper and dangerous operation. Verify proper
operation after servicing.
WARNING! Risk of Shock! Replace damaged wire with
type 105 ºC (221 ºF) rated wire. Wire must have high tem-
perature insulation.
240V FAN
GAS TUBE
IGNITOR
FLAME
SENSE
I
AUX300CE MODULE
S
AUX 1
AUX 2
8K1 WIRE
HARNESS
TO OPTIONAL
COMPONENTS
RED
BLACK
BATTERY PACK
6V DC (C X 4)
BROWN
GROUND
FAN
TO JUNCTION
CORD 220-240 VAC
OPTIONAL ON/OFF
WALL SWITCH
53

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6trsilp-aud

Table of Contents