Heat & Glo 6TRSI-AUD Owner's Manual
Heat & Glo 6TRSI-AUD Owner's Manual

Heat & Glo 6TRSI-AUD Owner's Manual

Natural gas, propane or butane as a balanced flue heater
Hide thumbs Also See for 6TRSI-AUD:
Table of Contents

Advertisement

Models:
6TRSI-AUD
6TRSILP-AUD
• Important operating
a n d m a i n t e n a n c e
instructions included.
WARNING: If the information in these
instructions is not followed exactly, a fi re
or explosion may result causing property
damage, personal injury, or death.
• DO NOT USE OR STORE FLAMMABLE
MATERIALS NEAR THIS APPLIANCE.
• DO NOT SPRAY AEROSOLS IN THE VICIN-
ITY OF THIS APPLIANCE WHILE IT IS IN
OPERATION.
• What to do if you smell gas
- DO NOT try to light any appliance.
- DO NOT touch any electrical switch. DO
NOT use any phone in your building.
- Immediately call your gas supplier from a
neighbor's phone. Follow the gas supplier's
instructions.
- If you cannot reach your gas supplier, call
the fi re department.
• Installation and service must be performed
by a qualifi ed installer, service agency, or the
gas supplier.
NOTICE
DO NOT DISCARD THIS MANUAL
• Read, understand and follow
these instructions for safe
installation and operation.
Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14
Owner's Manual
Installation and Operation
SAI Global
Ref No GSCS20164
AS4553:2008
• Leave this manual with
party responsible for use
and operation.
WARNING
HOT SURFACES!
Glass and other surfaces are hot during
operation AND cool down.
Hot glass will cause burns.
• DO NOT touch glass until it is cooled
• NEVER allow children to touch glass
• Keep children away
• CAREFULLY SUPERVISE children in same room as
fi replace.
• Alert children and adults to hazards of high temperatures.
High temperatures may ignite clothing or other fl ammable
materials.
• DO NOT PLACE ARTICLES ON OR AGAINST THIS
APPLIANCE.
• Keep clothing, furniture, draperies and other fl ammable
materials away.
This appliance has been supplied with an integral barrier
to prevent direct contact with the fi xed glass panel. DO
NOT operate the appliance with the barrier removed.
Contact your dealer or Hearth & Home Technologies if the
barrier is not present or help is needed to properly install one.
This is a room sealed appliance and no other ventilation is
required than what is provided.
SANS 1539:2008
1

Advertisement

Table of Contents
loading

Summary of Contents for Heat & Glo 6TRSI-AUD

  • Page 1 • Installation and service must be performed This is a room sealed appliance and no other ventilation is by a qualifi ed installer, service agency, or the required than what is provided. gas supplier. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 2 Save this manual for future reference. Heat & Glo, a brand of Hearth & Home Technologies 7571 215 Street West, Lakeville, MN 55044 Copyright 2013 • Printed in U.S.A. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 3: Congratulations

    The model information regarding your specifi c fi replace can be found on the rating plate usually located in the control area of the fi replace. SAI Global Certification Nº: DMS (mm) Type of Gas Model Number Serial Number xxxx-xxx Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 4: Sans Compliance

    You should only sign for acceptance of the installation when the installation is completed to your satisfaction. Note that your invoice is required in the event that you wish to make a guarantee claim. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 5: Table Of Contents

    D. Blower ........54 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 6 E. Contact Information ......75  = Contains updated information. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 7: Limited Lifetime Warranty

    All Parts and Material Except 1 Year as covered by Conditions, Exclusion, and Limitations listed Igniters, Electronic Components, and Glass 2 years Factory-installed blowers Molded refractory panels 3 years Firepots and burnpots Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 8 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 9 However, if you Melbourne Perth Sydney Fireplace Corner 444 Swan Street 277 Lord Street Richmond 3121 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 10: Listing And Code Approvals

    Columns highlighted in gray = The gas control valve supplied with this product is approved for a maximum inlet pressure of 3.40 kPa. For pressures over 3.40 kPa, an in line pressure regulator must be installed upstream from the gas control valve. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 11: User Guide

    (NOT SHOWN) SECTION 2.E. FIXED GLASS ASSEMBLY (NOT SHOWN) SECTION 9.E. MANTEL SECTION 5.D FAN KIT SECTION 2.C. HEARTH CLEAR SPACE SECTION 2.D. GRATE Figure 2.1 General Operating Parts Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 12: Fan Kit

    Contact your dealer or Hearth & Home Technologies if the barrier is not present or help is needed to properly install one. For more information refer to the instructions supplied with your decorative door or front. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 13: Lighting Instructions (Ipi)

    For additional information on operating your Hearth & Home Technologies fi replace, please refer to www.fi replaces.com. Final inspection by Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 14: Control Module Operation

    VAC wall outlet to which this appliance’s power cord is connected, must be wired to an in-line on/off switch. This is required for servicing and/or resetting the control module in the event of a control module LOCK-OUT. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 15: After Fireplace Is Lit

    Is it normal to see the pilot fl ame burn turned off. Some optional control systems available with IPI models may allow pilot fl ame to continually? remain lit. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 16: Maintenance And Service

    • Inspect draft shield to verify it is not damaged or missing. Hold glass in place with one hand and secure glass latches with the other hand. • Reinstall door or decorative front. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 17: Maintenance Tasks-Qualifi Ed Service Technician

    Use caution when cleaning these areas. Screw tips that have penetrated the sheet metal are sharp and should be avoided. • Remove all foreign objects. • Verify unobstructed air circulation. Figure 3.1 IPI Pilot Flame Patterns Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 18: Installer Guide

    HEATER MUST BE INSTALLED AND MANTEL AND FLUE PENETRATION COMPLETE MANTEL LEG PRIOR TO FINISH SHEETING (SECTION 5.D) SURROUND HEARTH EXTENSION GAS LINE (SECTION 11) Figure 4.1 Typical System Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 19: Design And Installation Considerations

    1/2 - 3/4 in. (13 mm - 19 mm) length, #6 or #8 Self-drilling screws Caulking material (149 °C (300 °F) minimum continuous exposure rating) One 1/4 in. (6 mm) female connection (for optional fan) Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 20: Framing And Clearances

    3 in. (76 mm) 56-5/8 17-3/4 39-1/2 56-5/8 6TRSI-AUD See Section D. 6TRSILP-AUD Mantel Projections mm 1295 1067 1829 1438 1003 914 1118 1438 Figure 5.1 Appliance Locations Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 21: Constructing The Appliance Chase

    * Adjust framing dimensions for interior sheathing (such as sheetrock) C** Add 12 in. (305 mm) for rear venting with one 90º elbow. Figure 5.2 Clearances to Combustibles Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 22: Mantel And Wall Projections

    Note: Zero clearance fi nishing allowed on sides of surround Millimeters and top of non-combustible board.  Inches Figure 5.6  Millimeters Figure 5.4 Clearances to Mantel Legs or Wall Projections (Acceptable on both sides of opening.) Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 23: Termination Locations

    53.1°-56.3° ............2 130 56.3°-59.0° ............2 290 59.0°-60.3° ............2 440 *910 mm minimum in snow regions Figure 6.1 Minimum Height From Roof To Lowest Discharge Opening Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 24 LP Gas cylinder. A fl ue terminal is considered to be a source of ignition. MINIMUM CLEARANCES REQUIRED FOR BALANCED FLUE TERMINALS OR THE FLUE TERMINALS OF OUTDOOR APPLIANCES Figure 6.3 Minimum Clearances for Termination Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 25: Vent Information And Diagrams

    (see Figure 7.1). must be installed. • Horizontal runs of vent do not require vertical rise; horizontal runs may be level. Vertical 8-1/2 in. (216 mm) Horizontal Figure 7.1 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 26 90º elbow, to allow the vent pipe to clear the top standoffs. Figure 7.3 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 27 14 ft. 4.26 m 5 ft. 1.52 m 16 ft. 4.88 m = 34 ft. (10.36 m) Maximum = 16 ft. (4.88 m) Maximum INSTALLED HORIZONTALLY Figure 7.4 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 28 12 ft. * 3.66 m* 4 ft. 1.22 m 12 ft. * 3.66 m* = 12 ft. (3.66 m) Maximum = 32 ft. (9.75 m) Maximum Figure 7.5 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 29 Failure to keep insulation or other material away from vent pipe may cause over heating and fi re. For alternative installations, other than depicted, contact your dealer for further information. Figure 7.6 RESTRICTOR PLATE Figure 7.7 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 30 HORIZONTAL PIPE SUPPORT PIPE LENGTH WALL FIRESTOP 90 DEGREE ELBOW CEILING WALL BRACKET FIRESTOP Flue system termination kits DVP-SERIES DVP-FBHT DVP-TVHW DVP-TRAP2 Figure 7.8 Flue Components and Terminations Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 31 1.22 m 16 ft. 4.88 m = 36 ft. (10.97 m) Maximum *No specifi c restrictions on this value EXCEPT cannot exceed 36 ft. (10.97 m) Figure 7.9 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 32 4 ft. 1.22 m 12 ft. 3.66 m 12 ft. 3.66 m = 12 ft. (3.66 m) Maximum = 32 ft. (9.75 m) Maximum INSTALLED HORIZONTALLY Figure 7.10 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 33 6-1/2 in. (165 mm) 18 in. (457 mm) Figure 7.11 One 45º Elbow Do not use a 45º elbow in corner installations. Use two 90º elbows instead. Figure 7.12 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 34 5.18 m 20 ft. 6.09 m INSTALLED = 32 ft. (9.75 m) Maximum = 3 ft. (914 mm) Maximum HORIZONTALLY = 12 ft. (3.66 m) Maximum Figure 7.14 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 35 12 ft. 3.66 m 8 ft. 2.44 m 15 ft. 4.57 m = 32 ft. (9.75 m) Maximum = 15 ft. (4.57 m) Maximum INSTALLED HORIZONTALLY Figure 7.16 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 36 8 ft. 2.44 m = 36 ft. (10.97 m) Maximum *No specifi c restrictions on this value EXCEPT = 8 ft. (2.44 m) Maximum INSTALLED Figure 7.18 HORIZONTALLY Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 37: Vent Clearances And Framing

    * Shows center of vent framing hole for top or rear venting. The center of the hole is 1 in (25 mm) above the center of the horizontal vent pipe. Figure 8.2 Wall Penetration Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 38: Install The Ceiling Firestop

    INSTALL ATTIC INSULATION SHIELDS BEFORE OR AFTER INSTALLATION OF VENT SYSTEM 3 FASTENERS PER SIDE CEILING FIRESTOP CEILING FIRESTOP INSTALLED BELOW CEILING INSTALLED ABOVE CEILING Figure 8.4 Installing the Attic Shield Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 39: Install Attic Insulation Shield

    • Bend all tabs inward 90º around the top of the shield. These tabs must be used to prevent blown insulation from getting between the shield and vent pipe, and to maintain air space clearance. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 40: Appliance Preparation

    The rear fl ue collar seal cap must remain attached to the rear fl ue collars if the fl ue system is attached to the top starting collars. Figure 9.3 Remove the seal cap. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 41: Rear Vent

    fi rebox) must remain attached if the fl ue system is at- tached to the rear starting collars. Figure 9.8 Cut the metal retaining band and fold the sides out. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 42: Installing The Non-Combustible Board

    • Bend out nailing tabs on each side. PILOT HOLES • Place the appliance into position. Figure 9.14 Proper Positioning and Securing of an Appliance Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 43: Covers Removal For Servicing

    (when applicable to the model). J. Air Shutter Setting Natural Gas Propane Butane BASE PAN 6TRSI-AUD 12.5 mm 6TRSILP-AUD Full Open Full Open Figure 9.16 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 44: Installing Vent Pipe

    fl ue at the horizontal elbow joint to prevent the elbow from rotating. Use screws no longer than 1/2 in. (13 mm). If predrilling screw holes, DO NOT penetrate inner pipe. INCORRECT Figure 10.4 Seams Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 45: Assemble Slip Sections

    • Only outer pipes are sealed, sealing the inner fl ue is not required. • All unit collar, pipe, slip section, elbow and cap outer fl ues shall be sealed. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 46: Disassemble Vent Sections

    Figure 10.10 Rotate Seams for Disassembly WALL STUD 8 FT. (2.44 m) FLUE OUTLET Figure 10.11 Align and Disassemble Vent Sections 1 in. MIN. (25 mm) Figure 10.12 Installing Support Brackets Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 47: Install Firestops

    fi restop pipe opening as a guide. • Frame the hole with framing lumber the same size as the ceiling joists. CEILING CEILING FIRESTOP Figure 10.16 Attic Firestop Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 48: Flue Termination

    DVP-TRAP2 can adjust 4 in. 102 mm (5-3/8 to 9-3/8) (132 mm to 238 mm) INTERIOR EXTERIOR Figure 10.17 Flueing through the Wall • The termination kit should pass through the wall fi restops from the exterior of the building. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 49: Heat Shield Requirements For Horizontal Termination

    • Caulk the perimeter of the fl ashing where it contacts the roof surface. See Figure 10.20. CAUTION! Risk of Fire! Follow the requirements of the Australian gas installation code for minimum height re- quirements above the roof. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 50: Assemble And Install Storm Collar

    • Tighten nut and make sure the collar is tight against the pipe section. STORM COLLAR • Caulk around the top of the storm collar. See Figure 10.21 SCREWS CAULK Figure 10.22 Figure 10.22 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 51: Gas Information

    Fittings and connections may have loosened Note: Consult local building regulations to properly size the during shipping and handling. gas supply line leading to the (Rp 1/2 in.) hook-up at the unit. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 52 fl ame. Fittings and connections could have loos- ened during shipping and handling. WARNING! Risk of Fire! DO NOT change valve settings. This valve has been preset at the factory. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 53: Electrical Information

    TO OPTIONAL COMPONENTS JUNCTION CORD OPTIONAL ON/OFF WALL SWITCH ORANGE GREEN (PILOT) (MAIN) BLACK BATTERY PACK 6V DC (C X 4) BROWN GROUND Figure 12.1 IPI Wiring Diagram /RC300AU Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 54: Blower

    REM300-HNG-AU • Keep remote control out of reach of children. • REM300-HNG-AU Transmitter • AAA Batteries (3) • Wall Holder • Drywall Anchor (2) • Screws (2) Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 55 Figure 12.6 Remote in Housing Figure 12.3 Temperature Scale 5. Close the housing door. See Figure 12.6. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 56 3 min. ON, 12 min. OFF FAN CORD FAN CORD LEARN BUTTON Figure 12.9 Programming RC300AU AUX 300 AUX 300 MODULE MODULE Figure 12.8 Plug Fan into AUX300CE Module Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 57 Use the SELECT button to select the current Select feature. Use the UP and DOWN arrows to toggle through the menu functions and value selec- tions in the submenus. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 58 fi replace is turned on. and AUX2 settings will be restored to the previous setting. NOTICE: The system will remember the previous FLAME HEIGHT setting and will automatically adjust after 10 seconds. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 59 NOTICE: No functions will be usable until child lock feature • Locate house circuit breaker for fi replace. is disabled. • Turn off the circuit breaker. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 60 At control module, turn off fi replace by sliding the ON/OFF/ Remote control or control REMOTE switch to OFF. Warning! Risk of Burns! Fireplace is module failure hot. Use caution when accessing module. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 61: Finishing

    2-7/16 3-7/16 4-7/16 5-7/16 6-7/16 7-7/16 Inches Millimeters  Inches  Millimeters Figure 13.2 Combustible Mantel Leg or Wall Projections (Acceptable on both sides of opening) Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 62: Appliance Setup

    Hearth & Home Technologies-approved optional acces- sories with this appliance. Using non-listed accessories could result in a safety hazard and will void the warranty. DO NOT MODIFY THIS APPLIANCE Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 63: Log Placement Instructions

    LOG #1 (SRV2049-700): Locate log #1 by placing log notches on the second and fi fth grate bars and push log against rear log locators. LOG #2 (SRV2049-701): Locate log #2 on grate with notches. Slide back against tabs. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 64 LOG #4 (SRV385-722): Place log #4 on 5th grate tines and rest its top into the groove on log #1. LOG #5 (SRV385-723): Position log #5 between the 3rd and 4th grate tines resting on the grooves in log #1 and log #2. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 65: Troubleshooting

    D. Pilot valve solenoid. Verify that 1.5 to 1.8 VDC is supplied to pilot solenoid from module. If below 1.5 volts, replace module. If 1.5 volts or greater, replace valve. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 66 B. Shutter Setting Check to assure correct shutter setting for your model and gas type. C. Gas Type Assure correct fuel matches unit gas model and components. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 67: Reference Materials

    FRONT VIEW RIGHT SIDE Location Inches Millimeters Location Inches Millimeters 1041 21-1/2 36-1/8 11-11/16 33-1/2 28-1/2 34-5/8 14-1/4 2-1/4 8-1/2 2-7/8 27-7/8 8-1/2 1019 36-1/8 Figure 16.1 Appliance Dimensions Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 68: Maintenance Tasks

    2. Replace batteries in remote transmitters and battery-powered receivers. Carbon Deposition 1. Appliances incorporating a live fuel effect, and designed to operate with luminous fl ames, may exhibit slight carbon deposition. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 69: Vent Components Diagrams

    14 in. (356 mm) 5 in. 12 in. (127 mm) (305 mm) 6 in. (152 mm) DVP-HVS (Vent Support) DVP-WS (Wall Shield Firestop) Figure 16.3 DVP vent components Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 70 14 in. (356 mm) 3/8 in. (10 mm) 1 in. (25 mm) 7-3/4 to 10-3/8 in. (197 to 264 mm) DVP-FBHT FireBrickTermination Cap Figure 16.4 DVP vent components Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 71 13-1/4 in. (367 mm) 14 in. 27-1/2 in. 24-5/8 in. (356 mm) (127 mm) (625 mm) DRC-RADIUS RF6M Cap Shield Roof Flashing Multi-pak Figure 16.5 DVP vent components Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 72: Service Parts

    Top Louver Assembly 392-182A Lower Door Assembly 2078-042 Dress Guard 2078-040 Blower 240Volt Assembly GFK-240V Junction Cord Assembly 2222-374 Additional service part numbers appear on following page. 2/14 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 73: Service Parts

    Defl ector, Pilot Air 2078-150 19.17 **Fuse for battery pack can be sourced locally, not a warranty item. Specs are 500mA~10A 3/4” long Additional service part numbers appear on following page. Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 74 Propane/Butane to Natural PB2N-6I-AUD Propane to Butane P2B-6I-AUD Natural to Propane N2P-6I-AUD Natural to Butane N2B-6I-AUD Pilot Orifi ce N (.020) 2098-520 Pilot Orifi ce P/ B (.0121) 2098-512 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...
  • Page 75: Contact Information

    5890485, 5941237, 6006743, 6019099, 6053165, 6145502, 6374822, 6484712, 6601579, 6769426, 6863064, 7077122, 7098269, 7258116, 7470729, 8147240 or other U.S. and foreign patents pending. 2000-945B Printed in U.S.A. - Copyright 2013 Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14...

This manual is also suitable for:

6trsilp-aud

Table of Contents