Heat & Glo 6TRSI-AUD Owner's Manual page 32

Natural gas, propane or butane as a balanced flue heater
Hide thumbs Also See for 6TRSI-AUD:
Table of Contents

Advertisement

Top Vent - Vertical Termination - (continued)
Three Elbows
H
2
Figure 7.10
32
V
1
Elbow only
6 in.
152 mm
1 ft.
305 mm
2 ft.
610 mm
3 ft.
914 mm
4 ft.
H
+ H
= 12 ft. (3.66 m) Maximum
1
2
V
2
INSTALLED
HORIZONTALLY
Heat & Glo • 6TRSI-AUD, 6TRSILP-AUD • 2078-980 Rev. Q • 2/14
H
+ H
1
2
1 ft.
305 mm
2 ft.
610 mm
3 ft.
914 mm
7 ft.
2.13 m
9 ft.
2.74 m
1.22 m
12 ft.
3.66 m
H
1
V
V
+ V
Minimum
H
2
1
2
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
*
12 ft.
V
+ V
+ H
+ H
= 32 ft. (9.75 m) Maximum
1
2
1
2
V
1
+ H
Maximum
1
2
1 ft.
305 mm
2 ft.
610 mm
3 ft.
914 mm
7 ft.
2.13 m
9 ft.
2.74 m
3.66 m

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

6trsilp-aud