CAUTION:
Use only the regulator provided. If a replacement is necessary, call our customer service center. The use of
unauthorized parts can create an unsafe condition and environment.
Your natural gas grill has been designed to operate on natural gas only, at a pressure of seven inches water column (7" W.C.).
Check with your gas utility for local gas pressure, because in some areas natural gas pressure varies. Also, check with your gas
company or with local building codes for instructions to install gas supply line or call a licensed and qualified installer.
It is recommended that an ON/OFF manual shut–off valve be installed at the gas supply source:
Outdoors after the gas line exits outside wall and before quick disconnect or before gas supply line enters ground.
Pipe sealing compound or pipe thread tape of the type resistant to the action of natural gas must be used on all male pipe
threads. Apply compound or tape to at least the first three to four threads when making connections.
Never store or use gasoline or other volatile substance in the vicinity of this grill.
During high pressure testing your gas grill and its individual shutoff valve must be disconnected from the gas supply piping
system. During any pressure testing of that system at least pressures in excess of 1/2 psi (3.5kPa).
During low pressure testing your gas grill must be isolated from the gas supply piping system by closing its individual manual
shutoff valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 1/2 psi (3.5kPa).
Warning: Burner valves are pre-tested at the factory to operate on natural gas. If you wish to convert or change it, be sure to
contact your grill distributor or dealer FIRST!
DANGER
To prevent fire or explosion hazard when testing for a leak:
1.
Always perform the "leak test" on page 14 before lighting the grill and each time the natural gas hose is connected for use.
2.
Do not smoke or allow other sources of ignition in the area while conducting a leak test.
3.
Conduct the leak test outdoors in a well-ventilated area.
4.
Do not use matches, lighters or a flame to check for leaks.
5.
Do not use grill until all leaks have been stopped. If you are unable to stop a leak, disconnect the natural gas supply, call for
gas appliance service or your local natural gas supplier.

Checking for Leaks

1. Make 2-3 oz. of leak solution by mixing one part liquid dishwashing soap with three parts water.
2. Make sure control knobs are in the "OFF" position.
3. Spray some solution on the connection points of the natural gas hose.