Vermont Castings RADVTCB Homeowner's Installation And Operating Manual page 34

Radvt series, radvtcs series direct vent gas heaters
Table of Contents

Advertisement

Radiance
®
Direct Vent Gas Heater
Initial Startup
Figure 61
1. After initial power up or
when RESET button is
pressed, the transmitter is
reset. The reset button is
located behind the battery
door of transmitter.
. During system reset, all fea-
tures of the LCD DISPLAY
will be visible. After one
second, the LCD will be
initialized. A typical reset display is shown in Figure 60.
Note the temperature scale is degree F.
3. Press ON button to select between °C and °F display.
It will exit setting mode automatically after 10 seconds
if no key is pressed. The transmitter will send an OFF
signal after reset.
4. After reset, the transmitter is operating in manual mode.
The room temperature is shown.
Manual Mode
Figure 62
1. Press the ON button once
to turn on the appliance with
max flame height.
. Press the OFF button to
decrease flame height. The
first two () presses will
decrease flame height to
lower level. The third press
will turn off the fireplace.
3. If the OFF button is held for more than three (3) seconds,
the fireplace will be shut off.
Thermostatic Mode
Figure 63
1. Press the AUTO/FLAME
button to enter the thermo-
static mode.
. In thermostatic mode, press
the ON / ▲ button or OFF
▼ button to set the desired
set temperature.
3. Once the setting is com-
pleted, the transmitter will
automatically turn on the
fireplace when the room
temperature is below the
set temperature and turn off the fireplace when the
room temperature is above the set temperature within
1 degree.
3434
°F
FP14
Fig. 61 Typical Reset
Display
FP2142
initial start up
°F
FP143
Fig. 62 Manual mode.
FP2143
manual mode
12/08
°F
/
°F
SET
FP144
Fig. 63 Thermostatic
mode.
FP2144
thermostat mode
12/08
4. There will be a slight delay in the response of the unit
(on/off) to a temperature. Room temperature is moni-
tored every three (3) minutes.
5. Press AUTO/FLAME button to exit the thermostatic
mode. The transmitter will be in the manual off mode
and the fireplace will be shut off.
Flame Height Setting for Thermostatic Mode
Figure 64
1. Hold AUTO/FLAME button
for five (5) seconds and
one number and flame
icon will appear in LCD
screen.
. Use the ON / ▲ or OFF /
▼ button to set the desired
flame height to 1 (min.) 
(medium) or 3 (max.).
3. If there is no input within
three (3) seconds, the new
setting will be transmitted
to the receiver. This setting
only affects auto mode operation.
4. The default setting for transmitter is  (medium).
3-Speed Blower Control
Figure 65
1. Press FAN button once to
enter blower speed setup
mode at low speed initially
and one of the three blade
icons will display dark-
ened on LCD display.
. Continue to press FAN
button to set the blower
speed you desire.
3. If there is no input within
three (3) seconds, the new
setting will be transmitted
to receiver. If the fireplace is on, the blower speed will
take effect right away; if the fireplace is off, the receiver
will remember this setting and blower is still off.
4. If you continue to press FAN button to the position that
all blades are gone, the FAN icon will disappear and
turn the blower off.
Blower On Delay Time and OFF Delay Time Setting
(Default 5 ON / 8 OFF)
Figure 66
1. Hold FAN button for five (5) seconds and two () num-
bers will appear in the LCD screen. The upper one is
ON Delay Time and the bottom is OFF Delay Time in
minutes.
FP147
Fig. 64 Flame height
setting.
FP2147
flame height setting
12/08
°F
FP145
Fig. 65 3 speed blower
control.
FP2145
3 speed fan
12/08
30004967