Customized Values; Serial Communication Conditions - Epson TM-L90 series Service Manual

Epson tm-l90 series line-thermal printer
Hide thumbs Also See for TM-L90 series:
Table of Contents

Advertisement

Confidential

Customized Values

Table 6-9 Customized values
Function
Select NV user memory
capacity
Select NV bit image
memory capacity
Select paper width
Select number of division
for head energizing
Select print density
Select paper type (mono
or color)
Select print speed

Serial Communication Conditions

Table 6-10 Serial communication conditions
Function
Selection
Baud rate
2400 bps, 4800 bps, 9600 bps, 19200 bps,
38400 bps, 57600 bps, 115200 bps
Parity
None
Odd
Even
Flow control
DTR/DSR control
XON/XOFF control
Data length
7 bits, 8 bits
6-16 Installation
Selection
1KB 64KB 128KB 192KB
None 64KB 128KB 192KB 256KB 320KB 384KB
38 mm
39 mm
80 mm (43 steps in increment of 1 mm, except for the size
from 71 mm to 79 mm)
Undivided energizing
Two-part energizing
Three-part energizing
Four-part energizing
× 0.7, × 0.75, × 0.8, × 0.85, × 0.9, × 0.95, × 1.0,
× 1.05, × 1.1, × 1.15, × 1.2, × 1.25, × 1.3, × 1.35, × 1.4
Single color
Two colors
Print speed level 1
Print speed level 9
Rev.B

Hide quick links:

Advertisement

Table of Contents
loading