Confidential
3. Pull out the lever shaft and remove one E2 type E retaining ring.
Lever shaft
E2
4. Remove the cover open lever.
Cover open lever
5. Remove the lead wire of the BM (black mark) detection set board from the hooks of the
platen holder.
Hooks
3-48 Disassembly and Assembly