Battery-Backed Write Cache Enabler - HP DL360 Maintenance And Service Manual

Hewlett-packard server user manual
Table of Contents

Advertisement

Removal and Replacement Procedures

Battery-Backed Write Cache Enabler

1. Power down the server. Refer to "Powering Down the Server" earlier in this chapter.
2. Remove the server from the rack. Refer to "Removing the Server from the Rack" earlier
in this chapter.
3. Remove the access panel. Refer to "Server Access Panel" earlier in this chapter.
4. Remove the PCI riser board assembly from slot 1. Refer to "PCI Riser Board Assembly"
earlier in this chapter.
5. Remove the battery module cable from the battery-backed write cache (BBWC) cable
clip (1).
6. Disconnect the BBWC cable from the SmartArray 5i Plus Controller connector (2) and
the BBWC battery module (3).
Figure 2-46: Disconnecting the battery-backed write cache cable
2-40
HP ProLiant DL360 Generation 3 Server Maintenance and Service Guide

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Proliant dl360 generation 3

Table of Contents