3.
Lift the complete burner and valve assembly upward, then turn
it sideways in fireplace opening to gain easy access to the
junction box. See Figure 56.
4.
Remove the two 5/16" Hex screws that secure the junction box
to the firebox, and remove the junction box. See Figure 57. Run
romex wire through the right rear corner of the fireplace and
into the firebox area. Secure wiring with the romex connec-
tor as required and install the duplex receptacle as shown in
Figure 58. Attach the black wire to the brass screw side of the
receptacle, and the white wire to the opposite side. Secure the
incoming ground wire under the green ground screw provided
on the receptacle.
Page 40
JUNCTION BOX WIRING
Figure 56
Figure 57
5.
If only installing the LK5 Accent Light kit, then remove the 7/8"
diameter knockout in the back of the junction box, install the
7/8" diameter protective grommet, and connect the wiring with
wire nuts as shown in Figure 58. There is a solid junction box
cover plate included with the LK5 kit that should be used on
the junction box if a duplex receptacle is not used.
6.
Once the junction box wiring is completed, re-install the junc-
tion box into the lower right corner of the firebox cavity using
the screws removed in step 4 as shown in Figure 59.
Figure 58
Figure 59