Millivolt Wiring - Empire Comfort Systems VFLL38FP30L-1 Installation Instructions And Owner's Manual

Contemporary linear vent-free fireplace
Table of Contents

Advertisement

Label all wires prior to disconnection when servicing controls. Wiring
errors can cause improper and dangerous operation. Verify proper
operation after servicing.
Millivolt thermopile is self powered, gas valve does not require 110
volts. Maximum length of 20 feet of 16 AWG to conductor wires is
to be used with all optional switches.
Check 750 Millivolt system Operation
Millivolt system and all individual components may be checked with
a millivolt meter 0-1000 MV range.
WIRING DIAGRAM
(OPTIONAL) THERMOSTAT
(FACULATIVE) THERMOSTAT
THERMOPILE
PILOT
VEILLEUSE
THERMOCOUPLE
(NATURAL)
29516-10-0713

MILLIvOLT WIRING

(OPTIONAL) WALL SWITCH
INTERRUPTEUR MURAL
(FACULTATIVE)
REMOTE CONTROL RECEIVER
(FACULTATIVE) CONTROLE E DISTANCE
DU RECEPTEUR
THERMOCOUPLE
GAS VALVE
(LPG)
Remote Receiver
Use the following steps to place the remote receiver adjacent to
the gas valve.
Attention: The remote receiver bracket is not used in this
installation.
1.
The remote receiver can not be placed beside the gas valve
and burner assembly.
2.
When facing the appliance, the remote receiver must be placed
to the left of the gas valve.
Refer to remote control installation and operating instructions for
more details on remote control.
H
(OPTIONAL) REMOTE/OFF/ON SWITCH
A DISTANCE/OUVERT/
FERME INTERRUPTEUR (FACULATIVE)
Figure 33
REMOTE CONTROL RECEIVER/
THERMOSTAT/CONTROLE E
DISTANCE DU RECEPTEUR
N
GAS VALVE
VALVE DE GAZ
IF ANY OF THE ORIGINAL WIRE
AS SUPPLIED WITH THIS UNIT
MUST BE REPLACED, IT MUST BE
REPLACED WITH NUMBER 18, 150 C
WIRE OR ITS EQUIVALENT.
SI UN DES FILS ELECTRIQUES
ORIGINAUX, VENANT DU FABRICANT
AVEC CETTE UNITE, DOIT ETRE
REMPLACE, VOUS DEVEZ LE
REMPLACER AVEC UN FIL
ELECTRIQUE DE NUMERO 18,
o
150 C DU L'EQUIVALENT.
o
Page 23