SERVICE DIAGNOSIS

The following diagnosis is only to be used as a guide to qualifi ed service personnel. Keating recommends that
you use a qualifi ed & licensed service company. (Equipment still under warranty requires it.) Call 1-800-KEATING
if you need assistance in locating a qualifi ed service company.
NOTE: To correctly and quickly diagnose the system, the chart below should be followed in sequential order.
TROUBLE SHOOTING CHART
PROBLEM
Main power light does not come on
Blower light does not come on
Burner light does not come on
Burner light comes on, then goes out
(after 2 1/2 seconds)
INCREDIBLE FRYING MACHINE™ - SERIES 2006
PROBABLE CAUSE
a. Fryer not plugged in.
b. Breaker has tripped.
c. Main power switch is faulty.
a. Thermostat not turned on.
b. If blower comes on, blower light is
faulty.
c. If Over Maximum Temperature light is
on, Hi-Limit has been activated.
d. If unit has a fi lter, drain handle not
locked into place.
• Check for fl ame at each burner.
If no fl ame is present at either burner:
a. Spark module is faulty.
• Check for fl ame at each burner.
If fl ame is present at both burners:
b. Burner light is faulty.
• Check for spark at each burner.
If no spark at either burner:
a. Spark electrode wires are not tight
or faulty.
b. Spark electrode is faulty or is out of
alignment.
• Check for spark at each burner.
If spark occurs at both burners:
c. Gas is not hooked up properly or
not turned on.
d. Spark electrode is faulty or is out of
alignment.
e. Combination gas valve is faulty.
SOLUTION
a. Plug fryer to an approved outlet.
Must be properly grounded.
b. Reset the breaker located on the
bottom of the control panel.
c. Replace the main power switch.
a. Set thermostat to desired
temperature.
b. Replace blower light.
c. Reset Hi-Limit after oil has cooled
down below 425°F. Correct problem
which caused Hi-Limit to activate.
(See page 20).
d. Secure drain handle in place behind
the bracket.
a. Replace spark module.
b. Replace burner light.
a. Tighten spark electrode wires or
replace.
b. See detail on page 27.
c. Turn manual gas valve on. If using
fl exible connector with quick
disconnect, make sure that the quick
disconnect is completely engaged.
d. Align spark electrode. Replace spark
electrode if faulty. Gap must be 1/8"
between electrode and pilot tube and
between pilot tube and burner
(See page 27).
e. Replace combination gas valve after
verifying it has voltage.
1-800-KEATING
|