Visual Manager User Interface
Note:
use Fibre Channel devices. This type of configuration is known as a Target Mode
configuration.
Note:
complete their individual power-ups.
60
Do not enable Target IDs unless there is a SCSI initiator on the bus that wants to
Discovery toggles between Enabled and Disabled.
Discovery Delay is the wait time after a power-up or reboot before
discovering SCSI devices.
HP recommends setting the value to at least 2 seconds to ensure all SCSI devices
Bus Reset on Boot toggles between Enabled and Disabled.
When enabled, the router will automatically reset SCSI buses during a power
up or reboot of the router.
Internal Termination toggles between Enabled and Disabled.
Caution:
If this configuration setting is incorrectly set, processing difficulties
may occur. Before changing this setting, evaluate the need for the change and
verify the desired setting. HP recommends backing up the router configuration
to an external file before making changes to this setting.
When enabled, internal termination of the selected SCSI bus is allowed. When
disabled, the SCSI Bus, not the router handles SCSI termination.
Buffered Tape Writes (default: Enabled) toggles between Enabled and
Disabled.
When enabled, Buffered Tape Writes enhance system performance. Buffered
Tape Writes return status on consecutive write commands prior to the tape
device receiving data.
Default Map (default: auto-assigned) sets the current mapping mode for the
selected bus.