Power And Input; Output - Extron electronics MPS 601 User Manual

Media presentation switcher
Hide thumbs Also See for MPS 601:
Table of Contents

Advertisement

Power and Input

AC power — Connect to standard AC power: 100 to 240 VAC, at 50 or 60 Hz.
A
3/16"
(5 mm) Max.
Figure 3.
RGBHV video inputs — Two
B
female 15-pin HD connectors for VGA input (numbered 1 and 2 on the rear panel). The
connectors accept analog VGA signals.
NOTE: The MPS 601 digitizes the RGBHV input signal. It does not scale or convert
video to a different resolution. The output signal resolution is the same as the
input resolution.
Analog audio inputs — Two female 3.5 mm TRS connectors. By default, input A is
C
associated with RGBHV video input 1, and input B is associated with RGBHV video
input 2. The analog input signal is digitized and embedded onto the HDMI output.
For additional audio input switching modes see
HDMI video inputs — Four female HDMI connectors for HDMI compliant audio and
D
video input (numbered 3 through 6 on the rear panel). Connect to any HDMI source
device using standard HDMI cables.

Output

HDMI video output — Connect an HDMI display device for output from the selected
E
input.
DC Power Cord
Captive Screw
Connector
Ground
+12 VDC
External
Power Supply
(12 VDC, 1 A )
AC Power Cord
Power Supply
Wiring
ATTENTION:
Always use a power supply provided by or specified
by Extron. Use of an unauthorized power supply
voids all regulatory compliance certification and may
cause damage to the supply and the end product.
Unless otherwise stated, the AC/DC adapters are
not suitable for use in air handling spaces or in wall
cavities. The power supply is to be located within
the same vicinity as the Extron AV processing
equipment in an ordinary location, Pollution Degree
2, secured to the equipment rack within the
dedicated closet, podium, or desk.
The installation must always be in accordance
with the applicable provisions of National Electrical
Code ANSI/NFPA 70, article 725 and the Canadian
Electrical Code part 1, section 16. The power supply
shall not be permanently fixed to building structure
or similar structure.
Audio Features
MPS 601 • Installation
on page 12.