Page 2
Protección del cables de alimentación • Los cables de alimentación eléctrica se deben protección aislante, que puedan encontrarse dentro use. In no event will Extron Electronics be liable for direct, indirect, or consequential instalar en lugares donde no sean pisados ni apretados por objetos que se puedan de la caja o alojamiento del producto, y que puedan apoyar sobre ellos.
Page 4
Quick Start Guide — MSW 4V rs & 4SV rs Installation Step 1 Turn all of the equipment off and AUTO SWIC disconnect it from the AUTO SWIC power source. 1U Rack Shelf 1/4 Rack Width False Front Step 2 Face Plate Select your mounting AUTO...
Table of Contents Quick Start Guide — MSW 4V rs & 4SV rs, cont’d Step 6 Chapter One • Introduction ............ 1-1 Power up the input and output devices, then connect power to the About this Manual ..............1-2 MSW.
Table of Contents, cont’d Appendix A • Specifications, Part Numbers, and MSW 4V rs and 4SV rs Accessories ..................A-1 Specifications ................A-2 Parts ....................A-5 Included parts .................A-5 Optional accessories ...............A-5 Chapter One Introduction About.this.Manual Features All trademarks mentioned in this manual are the properties of their respective owners. 68-1267-01.A 09.06 TOC-ii MSW 4V rs and 4SV rs • Table of Contents...
Introduction About this Manual • Contact closure remote control • Ability to detect an active signal The Extron MSW 4V rs and MSW 4SV rs are four-input, two parallel output, mini video switchers (MSWs). The MSWs are • Built-in video encoder to output composite video to a members of the Extron VersaTools line of basic distribution ®...
Installation and Operation Installation Mounting instructions On the standard rack shelf, the MSW mounts in one of four The 1U high, quarter rack width, MSW 4V rs and MSW 4SV rs locations to the rear of the rack or in one of four locations to the can be mounted on a rack shelf, under a desk, or on a tabletop.
Installation and Operation, cont’d Rear Panel Connections Furniture mounting Furniture mount the MSW using the optional MBU 123 VersaTools under-desk mounting kit (part #70-212-01) as follows: MSW 4SV rs RS-232 If necessary, remove the feet from the bottom of the MSW. Attach the mounting brackets to the MSW with the Tx Rx POWER...
Page 11
Installation and Operation, cont’d Switcher S-video output (MSW 4SV rs) — Connect an S-video display RS-232 or other device to this 4-pin mini DIN connector for the S-video output. Tx Rx S-video Inputs 1 through 4 (MSW 4SV rs) — For each input, DB9 Pinout (Female) connect an S-video source to one of these 4-pin mini DIN To control equipment...
Installation and Operation, cont’d Input selection Stripping the wires to expose less than the recommended amount causes them to slide out of the connector too easily, Input 1 through 4 LEDs — The Input LEDs identify the selected even if they are tightly pinched by the captive screws. input. Slide the leads into the supplied captive screw plug and Input 1 through 4 buttons — Each Input button selects the lock them, using an Extron Tweeker (small screwdriver).
Installation and Operation, cont’d Mode selection MSW 4V rs and 4SV rs To turn autoswitch mode on: Press and hold the Mode (Input 1) button. Press and hold the Auto (Input 3) button. Release the Mode and Auto buttons simultaneously. MODE NORMAL AUTO...
The switcher-initiated messages are listed below: — — — — (c) Copyright 2006, Extron Electronics, MSW Series Switchers, Vx.xx] Figure 3-1 — RS-232 connector wiring The switcher issues the copyright message and the input This port has the following RS-232 protocol: selected message when it first powers on.
Serial Communication, cont’d Using the command/response table The Command/response table for Simple Instruction Set (SIS) commands is shown at right. The symbols used throughout the table represent variables in the command/response fields. Lower and upper case letters are interchangeable, and command and response examples are shown throughout the table.
Serial Communication, cont’d Windows-Based Control Program The Extron Universal Switcher Control Program window (figure 3-4) displays the selected input and panel mode The Universal Switcher Control Program (part #29-031-01), is (Front-Panel [normal] or Auto-Switch). compatible with Windows 2000 and Windows XP or later, and it provides remote control of input selection and front panel switch mode selection.
Serial Communication, cont’d Updating the Firmware Extron periodically updates product firmware in conjunction with the release of new software revisions. When updating any Extron software to the latest revision level, please be sure to read the supplied release notes, or contact an Extron Application Engineer to determine if your Extron product requires a firmware update.
Serial Communication, cont’d A status bar, showing the progress of the upload appears MSW 4V rs and 4SV rs in the Firmware Loader window. The firmware upload to the switcher may take several minutes. Once the status bar has progressed fully from left to right across the indicator window, the Firmware Loader utility automatically resets the switcher.
Specifications, Part Numbers, and Accessories Parts Contact closure ......(1) 3.5 mm captive screw connector, 5 pole Contact closure pin configurations Included parts 1 = input 1, 2 = input 2, 3 = input 3, 4 = input 4, 5 = GND These items are included in each order of an MSW series mini Program control ......