Windows
-based Control Program, cont'd
7.
8.
9.
10.
MPS Series • Windows-based Control Program
4-4
Click OK to bring up the file selection window. Locate and select the file you
saved in step 2 and click Open.
Valid firmware update files have the file extension ".S19." Files with other file
extensions are not firmware update files.
After opening the file, click OK, then remove power from the unit. Power the
unit back up to start uploading the firmware update. The upload process may
take several minutes.
To ensure that the correct update file is listed, read the text in the window that
appears. If the desired file is not listed, click Cancel to return to the Firmware
Loader window.
Figure 4-4 — Firmware update confirmation window
The existing firmware in the unit will be erased once the power is
removed. Ensure the update file is correct before clicking OK. Using the
wrong update file will cause an error during firmware upload, and the
unit may lock up. If the unit locks up, call the Extron S
Technical Support Hotline for assistance.
After the upload is completed, click OK to return to the Firmware Loader
window.
Figure 4-5 — Firmware update completed window
Check the updated firmware version listed in the Firmware Loader window.
If necessary, click Upload Firmware File to repeat the firmware update
procedure. Otherwise, click Exit.