1. Connect the hose and gun.
a. Remove the plastic cap plug from the outlet fitting
and screw a conductive or grounded 3000 psi
airless spray hose onto fluid outlet.
b. Connect an airless spray gun to the other end of
the hose.
c. Do not use steel braided airless hose. Use nylon
braided airless hose only.
NOTE:
Do not use thread sealer on swivel
unions as they are made to self-seal.
Use thread seal on tapered male threads only.
2. Fill the packing nut/wet cup with
5 drops of Airlessco Throat Seal
Oil (TSO). See (Figure 5).
FIGURE 5
SETTING UP
To reduce the risk of static sparking, fire or
explosion which can result in serious bodily
injury and property damage, always ground
the sprayer and system components and the
object being sprayed, as instructed in the
safety warning section of this manual.
3. Flush the sprayer
As per "How To Flush" in this manual (Page 8).
WARNING
9