1. Be sure the gun safety latch is engaged and there
is no spray tip in the gun. Refer to page 14 on how
to lock the safety latch and the gun's safety features.
FIGURE 4
FIGURE 2
REMOVE SPRAY TIP.
ENGAGE GUN SAFETY
LATCH.
2. Pour enough clean, compatible solvent into a large,
empty metal pail to fill the pump and hoses.
3. Place the suction tube into the pail.
4. Turn the Prime Valve (Figure 6) to the
"OPEN" priming position.
5. Point the gun into the metal pail and hold a metal
part of the gun firmly against the pail. Refer to Figure 3.
To reduce the risk of static sparking
which can cause fire or explosion,
always hold a metal part of the gun firmly
against the metal pail when flushing. This
also reduces splashing.
FIGURE 3
MAINTAIN FIRM
METAL TO METAL
CONTACT BETWEEN
GUN AND CONTAINER
8

HOW TO FLUSH

6. Disengage the gun safety latch and squeeze the
gun trigger. Turn Pressure Control Knob (Figure 4)
Clockwise to increase pressure just enough to cycle
the pump.
7. Turn the PrimeValve to the "CLOSED" position.
This will allow solvent to be flushed through the pump,
hoses and gun. Allow the unit to operate until clean
solvent comes from the gun.
8. Release the trigger and engage the gun safety
latch.
9. Whenever you shut off the sprayer, follow the
"PRESSURE RELIEF PROCEDURE" (Page 11).