Philips 107E61/00 Service Manual page 19

17" crt colour monitor
Table of Contents

Advertisement

3. Click Bootcode-string, choose the third row and input the
following codes ''0x6e, 0x42, 0x41, 0x43, 0x4b, 4x74, 0x6f,
0x42, 0x4f, 0x4f, 0x54'', then click ''close window''.
4. Click ''load file'', bring up the following window as shown in Fig 11.
Fig. 11
5. Choose the Demic. Hex from C:\107E6, the left side of the window
will show the file name"313811707142...hex", click "3138117...hex"
of the left side of the window, then click "Load file",shown as Fig. 12.
Fig. 12
ISP (In System Program)
Step 5: Upgrade the firmware
(Fig. 10)
Fig. 10
Factory
Mode-------------
Indicator
Choose all the items of the Programming commands, then click
"AUTO (Run All Selected)", the software will upgrade the firmware,
the LED will extinguish several seconds, after finished the upgrade,
the monitor will stand-up automatically. Bring up the window as
shown in Fig. 18,which means you have finished the upgrade
successfully.
Fig. 18
Click"Quit Program", quit the program.
Turn off the monitor, then press
the LED light, then press
You will find, after upgrade, the version have already changed
As Shown in Fig. 19.
Fig. 19
Turn off the monitor to exit the factory mode.
107E6 CRT
Go to cover page
and
simultaneously till
button, bring up MAIN CONTROLS.
19