Alarm Codes And Descriptions - Lennox icomfort Setup Manual

Touch screen programmable communicating thermostat
Hide thumbs Also See for icomfort:
Table of Contents

Advertisement

Alarm ID
Message Name
10
Unknown Device Detected − DEVICE2
11
Missing DEVICE2
12
Incomplete System
14
Too Many Devices of the Same Type
18
Low Ambient HP Heat Lockout
19
High Ambient Auxiliary Heat Lockout
29
Over Temperature Protection
30
Low Temperature Protection
31
Lost Communication with DEVICE2
32
Asynchronous Reset DEVICE2
34
Must Program Unit Capacity for DEVICE2
35
Incorrect Operation of DEVICE2
105
Communication Problem
110
Low AC Line Voltage
113
High AC Line Voltage
114
AC Line Frequency/Distortion Problem
115
Low Secondary (24VAC) Voltage
116
High Secondary (24VAC) Voltage
120
Unresponsive DEVICE2
124
Active Subnet Controller Missing
Alarm Codes and Troubleshooting
Action required to Clear/Recover
Reconfigure the system. Press and hold Lennox Logo, press setup tab, press start, and press confirm. If still
persists, then check all DEVICE connections to make sure they are icomfort compatible.
Check all connections and cycle system power. If problem persists, then reconfigure the system (procedure
mentioned above).
Thermostat did not find an Indoor Unit. Check connections and cycle power. Replace board if no response.
Thermostat found more than one outdoor unit, or more than 1 indoor unit, or more than 1 thermostat connected
to the system. Check wiring and remove duplicate equipment.
Notification only − Outdoor Temp is below the Low Balance Point. HP will not be used to service a Heating Call.
Notification only − Outdoor Temp is above the High Balance Point. Indoor Unit (Furnace or Electric Heat) will not
be used to service a Heating Call.
Indoor Temp went above 99ºF during a heating or cooling call. Heating is not allowed. Check that Thermostat
Sensor is accurate. Check that Heating Equipment is not stuck ON (reversing value, etc.). Select system mode
to cooling to try and cool the indoor space.
Indoor Temp went below 40ºF. Cooling is not allowed. Check that cooling equipment is not stuck ON. Check
accuracy of the thermostat temperature. Try to heat the space to above 40ºF.
DEVICE2 is not communicating to the thermostat for more than 3 minutes. Check connections if fault persists,
then cycle power.
DEVICE2 is resetting by itself. Check power connections, and check 24VAC voltage at DEVICE. The alarm is
only cleared by pressing the clear button on the Installer Alerts Tab. If fault persists after checking connections,
replace board.
DEVICE2 is missing the programmed unit capacity. Go to DEVICE2 and program unit capacity manually. See
unit IOM for instructions.
DEVICE2 did not follow the command of the thermostat. Check connections and cycle power.
Equipment is unable to communicate. Check for miswired and/or loose connections and check for a high volt-
age source of noise close to the system (welder etc.).
Line Voltage Low (Voltage lower than nameplate rating). Check voltage.
Line Voltage High (Voltage higher than nameplate rating). Check voltage.
No 60 Hertz Power (Check voltage and frequency).
24 Voltage Low (Range is 18 and 30 volts ). Check voltage.
24 Voltage High (Range is 18 and 30 volts ). Check voltage.
Usually caused by delay in outdoor unit responding to indoor unit poling recycle power, check wiring.
Equipment lost communication with the thermostat. Check connections and cycle power on the thermostat.
Page 31