Operation Instructions/Flame Appearance; Maintenance - Empire Comfort Systems VFD26FM(2,3)0(N,W,C)(N,P)-2VFD26FM20NN-2 Installation Instructions And Owner's Manual

Vent-free gas fireplaces
Table of Contents

Advertisement

OpERATION INSTRUCTIONS/FLAME AppEARANCE

Flames from the pilot (rear right back side of the burner) as well
as the main flame should be visually checked as the log set is
installed.
In normal operation at full rate after 10 to 15 minutes, the flame
appearance should be sets of yellow flames.
NOTICE: All flames will be random by design, flame height will go
up and down.
Avoid any drafts that alter burner flame patterns. Do not allow fans to
blow directly into fireplace. Do not place a blower inside the burner
area of the firebox. Ceiling fans may create drafts that alter flame
patterns. Sooting and improper burning will result.
During manufacturing, fabricating and shipping, various components
of this appliance are treated with certain oils, films or bonding agents.
These chemicals are not harmful, but may produce annoying smoke
and smells as they are burned off during the initial operation of the
appliance, possibly causing headaches or eye or lung irritation. This
is a normal and temporary occurrence.
The initial break-in operation should last 2-3 hours with the burner
at the highest setting. Provide maximum ventilation by opening
windows or doors to allow odors to dissipate. Any odors remaining
after this initial break-in will be slight and will disappear with
continued use.
Keep the control compartment, logs and burner area surrounding
the logs clean by vacuuming or brushing area at least twice a year.
THE LOGS CAN GET VERY HOT – HANDLE ONLY WHEN
COOL.
Page 18

MAINTENANCE

WARNING
pERIODIC CLEANING – Refer to parts diagram for location of
items discussed below.
Do not use cleaning fluid to clean logs or any part of heater.
Logs - brush with soft bristle brush or vacuum with brush
attachment.
Remove loose particles and dust from the burner areas,
controls, piezo covers and grate.
Inspect and clean burner air intake hole. Remove lint or particles
with brush. Failure to keep air intake hole clean will result in
sooting and poor combustion.
ANNUAL CLEANING/INSpECTION – Refer to parts diagram for
location of items discussed below.
Inspect and clean burner air intake hole. Remove lint or particles
with vacuum or brush. Failure to keep air intake hole clean will
result in sooting and poor combustion.
Inspect and clean all burner ports.
Inspect ODS pilot for operation and accumulation of lint at air
intake holes.
Verify flame pattern and log placement for proper operation.
Verify smooth and responsive ignition of main burner.
Always turn off gas to the pilot before cleaning. For relighting, refer
to lighting instructions located on the rating plate of the log set.
Never obstruct the flow of the combustion and ventilation air. Keep
the front of the fireplace clear of all obstacles and materials.
Leave at least 36" clearance from the front of the fireplace.
Screen should be closed during operation.
30816-1-0912

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents