Omron V640-HAM11-ETN User Manual page 84

Cidrw system v640 series
Table of Contents

Advertisement

SECTION 7
Appendix
CIDRW Heads
V640-HS61
Four, 3.5-dia. holes
Mounting dimensions
Four M3 or 3.5-dia. holes
Item
Transmission frequency
Ambient temperature
Ambient humidity
Degree of protection
Insulation resistance
Dielectric strength
Vibration resistance
Shock resistance
Casing material
Weight
Cable length
Cable specification
CIDRW System
82
User's Manual
Antenna center
9
Coaxial cable 3.0 dia., standard length 2 m
21
29.2
50
Antenna center
9
21±0.2
134 kHz
Operating: 0 to +40°C
Operating/Storage: 35% to 85% (with no condensation)
IP60 (IEC60529)
20 MΩ min. between all terminals and the case (100 VDC M)
Leak current not to exceed 5 mA on application of 1000 VAC (50/60 Hz for 1 minute) between all
terminals and the case
Frequency: 10 to 150 Hz; double amplitude: 0.20 mm; acceleration: 15 m/s
8 minutes, 10 times each in X, Y, and Z directions
Shock of 150 m/s
2
in X, Y, and Z directions, 3 times each for 18 repetitions
ABS/epoxy resin
Stainless steel mount
Approx. 70 g
2 m
3-mm-dia. coaxial cable
Specifications
Storage: -15 to +65°C (with no icing)
(Unit: mm)