1.8.4 Installing carriage 2

(a) Wire tension adjustment
1. Install wire on carriage 2 by winding up as
shown below.
2. Remove the clip jig mounted on scanner drive
shaft.
3. Place the spring jig (wire) tension gauge on wire
holder and scanner drive shaft and then screw
it.
4. Remove the spring jig (wire) gauge and loosen
2 screws retaining slide plate.
5. To take up the winding slack of wire, move car-
riage 2 back and forth once (to the center of
scanner) and securely hold the carriage to the
left side frame.
6. Tighten 2 screws to secure slide plate.
December 2002 TOSHIBA TEC
Wire
Wire
Scanner drive shaft
Fig. 1-8-15
Scanner
drive shaft
Spring jig (Wire)
Fig. 1-8-16
Slide plate
Screw
Fig. 1-8-17
Slide plate
Screw
Fig. 1-8-18
1 - 79
e-STUDIO160/200/250 ADJUSTMENT ITEMS
Wire
061
Wire holder
Screw
062-1
062-2
Carriage 2
062-3