4 3
B
With lettering on outside of belt
4 3
and positioned as shown in
box on (D), slide new belt over
motor pulley (B).
4 6
Reposition bottom plate and 4
4 6
Phillips head screws. Ti g h t e n
s c rews secure l y.
The agitator brush roll
When to replace
To check condition of bru s h e s ,
4 8
move edge of a card across bot-
tom plate while turning agitator. To
maintain cleaning effectiveness, re p l a c e
agitator if b rushes do not touch card .
10
4 4
C
E
D
I n s e rt agitator through belt and
4 4
place belt in belt guide (C) on
a g i t a t o r.
Should the agitator shield (D)
become dislodged while replacing
the belt or the agitator, reposition it
as shown noting the placement of
its belt guide (E).
The edge groomers
When to replace
The edge groomers located on both
sides of the nozzle should be
replaced when they appear worn.
What to buy
When purchasing a pair of edge
groomers, ask for HOOVER part
No. 39511006.
How to replace
Disconnect cleaner from electrical
outlet.
Remove bottom plate as described in
"The belt" section (Fig. 41).
4 8
4 5
G
D
Grasp agitator firmly and fit it
4 5
into position by first sliding
end opposite the belt into the rec-
tangular slot (F) on side of cleaner.
Pull other side of agitator (G) into
place.
Turn agitator making sure belt is not
pinched between agitator and agi-
tator shield.
4 7
Lift off both old edge gro o m e r s
4 7
and slide new edge gro o m e r s
into position as shown.
Reposition bottom plate and secure
with 4 Phillips head screws.
What to buy
Your cleaner re q u i res either a 13" or a
15" agitator. When purchasing a new
a g i t a t o r, ask for one of the following:
13" - HOOVER part No. 48414-11 0 .
15" - HOOVER part No. 48414-11 5 .
How to re p l a c e
Disconnect cleaner from electrical
outlet.
Remove bottom plate, belt and agi-
tator following directions in "The
belt" section beginning with Fig. 41.
Discard old agitator.
Continue following the directions in
"The belt" section to reposition belt,
new agitator and bottom plate.