Preventative Maintenance; Regulator Service; Impco (Beam) Regulator Service; Regulator Drain Plug (Some Models) - Kohler CH18-745 Service Manual

Horizontal crankshaft
Hide thumbs Also See for CH18-745:
Table of Contents

Advertisement

Kohler Engine Parts Call K&T 606-678-9623 or 606-561-4983
Section 5A
LPG Fuel Systems

Preventative Maintenance

The regulator is preset at the factory and generally
requires no further adjustment. No periodic service is
required. Over time, depending on fuel quality, operating
environment, and system performance, fuel deposits
can accumulate inside the regulator. Those regulators
containing a drain plug (Nikki) should be drained every
500 hours to remove any accumulated deposits. See
Figure 5A-23.
Regulator Drain Plug
Figure 5A-23. Regulator Drain Plug (some models).
1. Turn supply valve off, run engine out of fuel, and
turn off ignition switch.
2. Disconnect and ground the spark plug leads.
3. Remove the 1/8" pipe plug from bottom of
regulator and drain any accumulated deposits.
See Figure 5A-23.
4. Reinstall plug using pipe sealant with Teflon
(Loctite
®
592 or equivalent) on threads and tighten
securely. If required, a replacement plug is
available as Kohler Part No. X-75-23-S.
5A.12

Regulator Service

Every 1500 hours it is recommended that
disassembly, cleaning, and resetting of the regulator
be performed using the regulator rebuilding kit
available. Specific instructions are included in the
rebuilding kit. Perform the regulator service following
the instructions provided. As all adjustments and
settings must be reset using specific test equipment,
this must be performed by qualified LP personnel only.

Impco (Beam) Regulator Service

Kohler repair kit 24 757 40-S should be used to service
the regulator every 1500 hours, or whenever cleaning
and servicing is required.
Nikki Regulator Service
Kohler repair kit 24 757 39-S should be used every
1500 hours.
®
www.mymowerparts.com

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents