Kohler COMMAND CV17-745 Service Manual page 133

Vertical crankshaft
Table of Contents

Advertisement

Kohler Engine Parts Call K&T 606-678-9623 or 606-561-4983
Phillips Head
Screws
Torx Head Screws
Figure 8-41. Removing Solenoid Screws.
3. If the solenoid was mounted with Phillips head
screws, separate the solenoid and plunger spring
from the drive end cap. If the solenoid was
mounted with external Torx head screws, the
plunger is part of the solenoid, unhook the plunger
pin from the drive lever. Remove the gasket from
the recess in the housing. See Figures 8-42 and
8-43.
Electrical System and Components
Figure 8-42. Solenoid Removed from Starter.
Figure 8-43. Removing Plunger.
4. Remove the two thru (larger) bolts. See Figure
www.mymowerparts.com
8-44.
Section 8
8
8.29

Advertisement