Kohler COMMAND CV17-745 Service Manual page 123

Vertical crankshaft
Table of Contents

Advertisement

Kohler Engine Parts Call K&T 606-678-9623 or 606-561-4983
Figure 8-28.
3. Plug the tester into a 110 volt AC outlet and turn
on the power switch. The ''POWER'' light should
be illuminated and one of the four status lights
may be on as well. See Figure 8-22. This does
not represent the condition of the part.
(-)
Figure 8-29. Connections for Testing Charging System.
DC Voltmeter
(+)
Battery
www.mymowerparts.com
Electrical System and Components
4. Press the ''TEST'' button until a "click" is heard
and then release. See Figure 8-23. Momentarily
either the ''HIGH'', ''LOW'', or ''SHORT'' light will
flash.
a. If the "HIGH" light flashes on/off, the part is
good and may be used.
b. If any other light is displayed* the rectifier is
faulty and should not be used.
*NOTE: A flashing "LOW" light can also occur as a
result of an inadequate ground lead
connection. Make certain connection location
is clean and clamp is secure.
Rectifier-Regulator
Ammeter
Section 8
8
Flywheel
Stator
8.19

Advertisement

Table of Contents
loading