Chapter 8
 
F-8-117
Pickup Unit 1
F-8-118
Pickup Unit 2
2) Disconnect the connector [1], and remove the
screw; then, detach the cassette pickup solenoid [3].
3) Remove the bushing and the 5 screws [4]; then,
detach the sensor base [5].
F-8-119
8-72
8.8.4.8 Mounting the Sensor
Mounting Plate
iR2270 / iR2870 / iR3570 / iR4570
Take care not to orient the pickup unit facing down
when mounting the sensor base; otherwise, the gears
will fall out.
1) After fitting the bushing [1] to the frame, mount the
gear shaft [2].
F-8-120
2) Fit the 6 points [A] indicated in the figure in the
holes of the base; then, mount the sensor base [2]
using 4 screws [1].
F-8-121
3) Mount the gear [1] and the E-ring [2].
Be sure not to leave out the pickup solenoid [1]. When
mounting it, be sure that the stop [2] is fully engaged
0007-6568