BATTERY WILL NOT
CHARGE AND ELECTRIC
STARTER WILL NOT
OPERATE
The battery-charging (ACG) circuit
and the electric starter relay circuit
are protected by the 10, 30-ampere
main fuses and 90-ampere ACG fuse.
If the fuse burns out, the engine will
not charge the battery, and the
electric starter will not operate.
The ignition switch is protected by
the 10-ampere main fuse. If the fuse
burns out, the engine will not start or
run, and the power trim/tilt switch
will not oprate.
TAKING CARE OF UNEXPECTED PROBLEMS
Fuse Replacement
Main Fuse
1.
With the engine stopped, remove
the engine cover.
2.
Remove the fuse covers.
3.
Remove and inspect the fuses. If a
fuse is burnt out, install a
replacement fuse of the specified
rating. The outboard motor is
supplied with spare fuses in the
fuse holders.
10 A, 30 A
MAIN FUSES:
Never use a f use with a rating
greater than specif ied. Serious
damage to the electrical system
could result.
FUSE COVER
FUSE (10A, 30A)
SPARE FUSE (10A, 30A)
4.
Reinstall the fuse covers and the
engine cover.
Before further operation, try to
determine and correct the electrical
problem that caused the fuse to
burn out. An uncorrected electrical
problem may cause the fuse to
burn out again.