Battery Will Not Charge And Electric Starter Will Not Operate - Honda Marine BF115A Owner's Manual

Hide thumbs Also See for Marine BF115A:
Table of Contents

Advertisement

BATTERY WILL NOT
CHARGE AND ELECTRIC
STARTER WILL NOT
OPERATE
The battery-charging (ACG) circuit
and the electric starter relay circuit
are protected by the 10 and 30-
ampere main fuses and 90-ampere
ACG fuse. If a fuse burns out, the
engine will not charge the battery,
and the electric starter will not
operate.
The ignition switch is protected by
the 10-ampere main fuse. If the fuse
burns out, the engine will not start or
run, and the power trim/tilt switch
will not operate.
TAKING CARE OF UNEXPECTED PROBLEMS
Fuse Replacement
Disconnect the battery cable at the
battery negative ( ) terminal bef ore
replacing the f use.
Failure to do so may cause a short
circuit.
Main Fuse
1.
Stop the engine and disconnect the
battery cable.
2.
Remove the engine cover.
3.
Remove the fuse covers.
4.
Remove and inspect the fuses. If a
fuse is burnt out, install a
replacement fuse of the specified
rating. The outboard motor is
supplied with spare fuses in the
fuse holders.
MAIN FUSE RATINGS:
10 A, 30 A
Never use a f use with a rating
greater than specif ied. Serious
damage to the electrical system could
result.