For Left Rear Piping - LG LS-E0960CL Service Manual

Room air conditioner
Hide thumbs Also See for LS-E0960CL:
Table of Contents

Advertisement

For left rear piping

3. Insert the connecting cables, the drain pipe and
connecting piping through the piping hole on
the wall.
4. Connect the piping and the indoor tubing, and
drain hose and drain pipe and place the drain
pipe into the chassis.
• Don't connect the cable to the indoor unit.
• Make a small loop for easy connection later.
• Glue up the connection portion of drain hose and
drain pipe.
Pipe Size
Liquid Side (1/4")
Gas Side (3/8")
Gas Side (1/2")
5. Bend the drain hose and bind the drain hose,
the piping and the connecting cables altogether.
Taping
Tubing holder
Push
2
Torque
1.8kg . m
4.2kg . m
5.5kg . m
Drain hose
Hook
1
Installation plate
To remove the holder,
press the bottom of
chassis near the holder
upward and pull the tab
out of its hole.
Outdoor
Indoor unit tubing
Spanner
Drain hose
-27-
Pull
Pull
Tubing holder
Pull
2
1
Press
Drain hose
Indoor
Connecting cable
Connecting piping
Drain pipe
Pipings
Flare nut
Torque wrench
Plastic bands
Insulation material
Drain pipe
Adhesive

Hide quick links: