Heating Mode Operation - LG LS-E0960CL Service Manual

Room air conditioner
Hide thumbs Also See for LS-E0960CL:
Table of Contents

Advertisement

Auto Operation for Soft Dry
The Setting temperature will be same that of auto operation for Cooling.
- Compressor ON temperature; Setting temperature +0.5°C
- Compressor OFF temperature; Setting temperature -0.5°C
Auto Operation for Heating
Intake Air temp.
Setting temp.

7. Heating Mode Operation

The unit will operate according to the setting by the remote controller and the operation diagram is shown as fol-
lowing.
Intake Air temp.
Setting temp. +3 C
(Compressor OFF)
Setting temp.
(Compressor ON)
INDOOR FAN SPEED
COMPRESSOR
• A point; The indoor pipe temperature to be 35 C.
The indoor fan operates minimum 10sec. even if falls lower than 35 C.
• B point; The indoor fan operates minimum 10sec.
minimum
1 min.
Hot
Start
Selecting
OFF
LOW
fan speed
ON
below 20°C
20°C
A
minimum
10sec.
10sec.
LOW
OFF
LOW
OFF
-16-
Over 20°C~below 21°C
Intake air temperature +0.5°C
B
minimum
10sec.
Selecting
LOW
fan speed
ON
A
OFF
OFF

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents