LG LS-E0960CL Service Manual page 23

Room air conditioner
Hide thumbs Also See for LS-E0960CL:
Table of Contents

Advertisement

2) Indoor Unit Installation
The mounting wall should be strong and solid enough
to protect it from the vibration.
1.Mount the installation plate on the wall with four
Type "A" screws.
(if mounting the unit on the concrete wall, consider
using anchor bolts.)
• Always mount the Installation plate horizontally by
aligning the marking-off line by means of the
thread and a level.
2. Drill the piping hole with 70mm dia. holecore
drill.
• Line according to the arrows marked on lower the
left and the right side of the Installation Plate.
The meeting point of the extended line is the cen-
ter of the hole.
• Drill the Piping hole at either the right or the left
and the hole should be slightly slanted to the out-
door side.
Type "A" screw
Weight
The lower left and right side of Installation
Plate
Left rear piping
80mm
ø70mm
Left rear piping
Center
ø70mm
Indoor
-23-
Installation plate
Marking-off line
Thread
8K, 9K Btu
Right rear piping
50mm
11K, 12K, 14K Btu
Right rear piping
A
A
A
A
ø70mm
WALL
Outdoor
ø70mm
Center

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents