LG LS-E0960CL Service Manual page 30

Room air conditioner
Hide thumbs Also See for LS-E0960CL:
Table of Contents

Advertisement

2) Connection of the cable
1. Remove the cover control from the unit by loosen-
ing the screw.
Connect the wires to the terminals on the control
board individually as the following.
1) Cooling only type
Terminals on the outdoor unit
Color of Wires
Color of Wires
Terminals on the indoor unit
2) Cooling & Heating type
Terminals on the outdoor unit
Color of Wires
Color of Wires
Terminals on the indoor unit
2. Secure the cable onto the control board with the holder
(clamper).
3. Refix the cover control to the original position with the
screw.
4. Use a recognized circuit breaker 16A between the power
source and the unit. A disconnection device to adequately
disconnect all supply lines must be fitted.
The length of the power supply cord should be over 1.8m measured from the power supply cord entry of the cabinet to the
middle of the live pin of the plug
The power cord connected to the indoor unit should
be complied with the following specifications (Type
H05VV-F approved by HAR or SA)
2(N)
1(L)
BROWN
BLUE GREEN/YELLOW
BROWN BLUE GREEN/YELLOW
1(L)
2(N)
2(N)
3
4
1(L)
BROWN BLUE
BROWN BLUE
G/Y
G/Y
BLACK
BLACK
RED
RED
BLACK
BROWN
BLUE
G/Y
RED
BROWN BLUE
G/Y
RED
1(L)
2(N)
3
4
NORMAL CROSS-
SECTIONAL AREA
1.0mm
2
(9K, 12K Cooling & 9K Heat pump)
Terminal block
(Pillar terminal)
Over 5mm
Holder for
power supply
cord
Cover control
Connecting cable
(12K Heat pump)
The connecting cable connected to the indoor and
outdoor unit should be complied with the following
specifications (Rubber insulation, type H07RN-F
approved by HAR or SA)
-30-
Outdoor unit
Terminal block
(Pillar terminal)
Over 5mm
Holder for
power supply
cord
Cover control
Connecting cable
Outdoor unit
NORMAL CROSS-
SECTIONAL AREA
1.0mm
2