Functions - LG LS-E0960CL Service Manual

Room air conditioner
Hide thumbs Also See for LS-E0960CL:
Table of Contents

Advertisement

Functions

Indoor Unit
Operation ON/OFF by Remote controller
Sensing the Room Temperature
Room temperature sensor. (THERMISTOR)
Room temperature control
Maintains the room temperature in accordance with the Setting Temp.
Starting Current Control
Indoor fan is delayed for 5 sec at the starting.
Time Delay Safety Control
Restarting is inhibited for approx. 3 minutes.
Indoor Fan Speed Control
High, Med, Low
Operation indication Lamps (LED)
--- Lights up in operation
--- Lights up in Sleep Mode
--- Lights up in Timer Mode
--- Lights up in Deice Mode (for Heating Model)
OUTDOOR --- Lights up in compressor operation (for Cooling Model)
Soft Dry Operation Mode
Intermittent operation of fan at low speed.
Sleep Mode Auto Control
The fan is switched to low(Cooling), med(Heating) speed.
The unit will be stopped after 1, 2, 3, 4, 5, 6, 7 hours.
Natural Air Control by CHAOS Logic
The fan is switched to intermittent or irregular operation
The fan speed is automatically switched from high to low speed.
Airflow Direction Control
The louver can be set at the desired position or swing
up and down automatically.
Deice (defrost) control (Heating)
Both the indoor and outdoor fan
stops during deicing.
Hot-start Control (Heating)
The indoor fan stops until the
evaporator piping temperature will be
reached at 28°C.
-3-

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents